Inspection [08/2015 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSPECT SHIFT SOLENOID VALVE SR
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Shift solenoid valve SR connector terminal - Shift solenoid valve SR body 20°C (68°F) 11 to 15 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Shift Solenoid Valve SR) - Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
Measurement Condition Specified Condition - Battery positive (+) → Shift solenoid valve SR connector
- Battery negative (-) → Shift solenoid valve SR body
Valve moves and makes an operating noise If the result is not as specified, replace the solenoid valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SL1 AND SL2
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Shift Solenoid Valve) - Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
Measurement Condition Specified Condition - Battery positive (+) with a 21 W bulb → Terminal 1
- Battery negative (-) → Terminal 2
Valve moves and makes an operating noise If the result is not as specified, replace the solenoid valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SLT AND SLU
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 -2 20°C (68°F) 5.0 to 5.6 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Shift Solenoid Valve) - Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
Measurement Condition Specified Condition Battery positive (+) with a 21 W bulb → Terminal 2 Battery negative (-) → Terminal 1 Valve moves and makes an operating noise If the result is not as specified, replace the solenoid valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE S1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body 20°C (68°F) 11 to 15 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Shift Solenoid Valve S1) - Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
Measurement Condition Specified Condition - Battery positive (+) → Shift solenoid valve S1 connector
- Battery negative (-) → Shift solenoid valve S1 body
Valve moves and makes an operating noise If the result is not as specified, replace the solenoid valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE S2
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body 20°C (68°F) 11 to 15 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Shift Solenoid Valve S2) - Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
Measurement Condition Specified Condition - Battery positive (+) → Shift solenoid valve S2 connector
- Battery negative (-) → Shift solenoid valve S2 body
Valve moves and makes an operating noise If the result is not as specified, replace the solenoid valve.
- Measure the resistance according to the value(s) in the table below.