On-Vehicle Inspection [08/2015 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK SHIFT LOCK OPERATION
- Move the shift lever to P.
- Turn the ignition switch off.
- Check that the shift lever cannot be moved from P.
- Turn the ignition switch to on (IG), depress the brake pedal and check that the shift lever can be moved to other positions.
If the operation cannot be performed as specified, inspect the transmission floor shift assembly and shift lock control ECU.
- CHECK SHIFT LOCK RELEASE BUTTON OPERATION
- When operating the shift lever with the shift lock release button pressed, check that the lever can be moved to any position.
If the operation cannot be performed as specified, check the transmission floor shift assembly.
- When operating the shift lever with the shift lock release button pressed, check that the lever can be moved to any position.
- CHECK SHIFT LOCK CONTROL ECU
- Measure the voltage and resistance according to the value(s) in the table below.
HINT:
Do not disconnect the shift lock control ECU connector.
Standard Voltage and resistance
Tester Connection Condition Specified Condition F75-8 (IG) - F75-1 (E) Ignition switch ON 11 to 14 V F75-8 (IG) - F75-1 (E) Ignition switch off Below 1 V F75-4 (STP) - F75-1 (E) Brake pedal depressed 11 to 14 V F75-4 (STP) - F75-1 (E) Brake pedal released Below 1 V F75-1 (E) - Body ground Always Below 1 Ω - Disconnect the shift lock solenoid connector from the shift lock control ECU.
- Measure the voltage according to the value(s) in the table below.
HINT:
Do not disconnect the shift lock control ECU connector.
Standard Voltage
Tester Connection Condition Specified Condition 1 (SLS+) - 2 (SLS-) Ignition switch off Below 1 V 1 (SLS+) - 2 (SLS-) Ignition switch ON Below 1 V Ignition switch ON and brake pedal depressed 11 to 14 V TEXT IN ILLUSTRATION*a Component without harness connected
(Shift Lock Control ECU)If the result is not as specified, replace the transmission floor shift assembly.
- Measure the voltage and resistance according to the value(s) in the table below.
- CHECK SHIFT LOCK SOLENOID
- Disconnect the shift lock solenoid connector from the shift lock control ECU.
- Measure the resistance according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 1 (SLS+) - 2 (SLS-) Always 101 to 123 Ω 3 (E2) - 4 (P) Shift lever in P 10 kΩ or higher 3 (E2) - 4 (P) Shift lever not in P Below 1 Ω TEXT IN ILLUSTRATION*a Component without harness connected:
(Shift Lock Control Solenoid) - Apply 12 V of battery voltage to the shift lock solenoid and check that the valve moves and makes an operating noise.
OK
Measurement Condition Specified Condition - Battery positive (+) → Terminal 1 (SLS+)
- Battery negative (-) → Terminal 2 (SLS-)
Solenoid moves and makes an operating noise If the result is not as specified, replace the transmission floor shift assembly.