Hazard Warning Switch Circuit [07/2014 - ]: Procedure
- READ VALUE USING TECHSTREAM (HAZARD FLASHER SWITCH)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- According to the display on the Techstream, read the Data List.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Hazard Flasher Switch Hazard warning signal switch /
OFF or ONOFF: Hazard warning signal switch off
ON: Hazard warning signal switch on- OK
Normal conditions listed above are displayed.
NG → See step 2
OK → See step 7
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY)
- Disconnect the D101 combination meter assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition D101-1 (B) - Body Ground Always 11 to 14 V TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Combination Meter Assembly)
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (TELLTALE LIGHT ASSEMBLY (HAZARD WARNING SIGNAL SWITCH) - COMBINATION METER ASSEMBLY)
- Disconnect the D115 telltale light assembly (hazard warning signal switch) connector.
- Disconnect the D101 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition D115-4 (TB) - D101-3 (HAZ) Always Below 1 Ω D115-5 (E) - Body Ground Always Below 1 Ω D115-4 (TB) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- REPLACE TELLTALE LIGHT ASSEMBLY (HAZARD WARNING SIGNAL SWITCH)
- Replace the telltale light assembly (hazard warning signal switch). Refer to REMOVAL [07/2014 - ] .
NEXT: Go to next step
- READ VALUE USING TECHSTREAM (HAZARD FLASHER SWITCH)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- According to the display on the Techstream, read the Data List.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Hazard Flasher Switch Hazard warning signal switch /
OFF or ONOFF: Hazard warning signal switch off
ON: Hazard warning signal switch on- OK
Normal conditions listed above are displayed.
NG → See step 6
OK → END (TELLTALE LIGHT ASSEMBLY (HAZARD WARNING SIGNAL SWITCH) WAS DEFECTIVE)
- REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [07/2014 - ]
- PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [07/2014 - ]