DTC P0351-P0354; Ignition Coil "A" Primary / Secondary Circuit [12/2012 - 10/2015]: Procedure
- CHECK HARNESS AND CONNECTOR (IGNITION COIL ASSEMBLY - BODY GROUND)
- Disconnect the ignition coil assembly connectors.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition B12-4 (GND) - Body ground Always Below 1 Ω B11-4 (GND) - Body ground Always Below 1 Ω B10-4 (GND) - Body ground Always Below 1 Ω B9-4 (GND) - Body ground Always Below 1 Ω
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 2
- CHECK TERMINAL VOLTAGE (POWER SOURCE OF IGNITION COIL ASSEMBLY)
- Disconnect the ignition coil assembly connectors.
*a Front view of wire harness connector
(to Ignition Coil Assembly) - Turn the ignition switch to ON.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition B12-1 (+B) - B12-4 (GND) Ignition switch ON 11 to 14 V B11-1 (+B) - B11-4 (GND) Ignition switch ON 11 to 14 V B10-1 (+B) - B10-4 (GND) Ignition switch ON 11 to 14 V B9-1 (+B) - B9-4 (GND) Ignition switch ON 11 to 14 V
Result:
NG
See step 5
Result:
OK
See step 3
- Disconnect the ignition coil assembly connectors.
- CHECK HARNESS AND CONNECTOR (IGNITION COIL ASSEMBLY - ECM)
- Disconnect the ignition coil assembly connectors.
- Disconnect the ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition B12-2 (IGF) - B77-51 (IGF1) Always Below 1 Ω B11-2 (IGF) - B77-51 (IGF1) Always Below 1 Ω B10-2 (IGF) - B77-51 (IGF1) Always Below 1 Ω B9-2 (IGF) - B77-51 (IGF1) Always Below 1 Ω B12-3 (IGT1) - B77-57 (IGT1) Always Below 1 Ω B11-3 (IGT2) - B77-56 (IGT2) Always Below 1 Ω B10-3 (IGT3) - B77-55 (IGT3) Always Below 1 Ω B9-3 (IGT4) - B77-54 (IGT4) Always Below 1 Ω B12-3 (IGT1) or B77-57 (IGT1) - Body ground Always 10 kΩ or higher B11-3 (IGT2) or B77-56 (IGT2) - Body ground Always 10 kΩ or higher B10-3 (IGT3) or B77-55 (IGT3) - Body ground Always 10 kΩ or higher B9-3 (IGT4) or B77-54 (IGT4) - Body ground Always 10 kΩ or higher B12-2 (IGF), B11-2 (IGF), B10-2 (IGF), B9-2 (IGF) or B77-51 (IGF1) - Body ground Always 10 kΩ or higher
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- CHECK WHETHER DTC OUTPUT RECURS (DTC P0351, P0352, P0353 OR P0354)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Clear the DTCs.
Refer to DTC CHECK / CLEAR [12/2012 - ]
Powertrain > Engine and ECT > Clear DTCs
- Shuffle the arrangement of the ignition coil assemblies (among No. 1 to No. 4 cylinders).NOTE:
Do not change the location of the connectors.
- Perform a simulation test.
- Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
- Read the DTCs.
Powertrain > Engine and ECT > Trouble Codes
Result
Result Proceed to Same DTC output A Different ignition coil DTC output B HINT:
Perform "Inspection After Repair" after replacing the ignition coil assembly.
Refer to INITIALIZATION [12/2012 - ]
Result:
A
REPLACE ECM: REMOVAL [12/2012 - ]
Result:
B
REPLACE IGNITION COIL ASSEMBLY: REMOVAL [12/2012 - ]
- CHECK HARNESS AND CONNECTOR (IG2 RELAY - IGNITION COIL ASSEMBLY)
- Disconnect the ignition coil assembly connectors.
- Remove the IG2 relay from the engine room relay block and junction block assembly.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition B12-1 (+B) - IG2 relay terminal 5 Always Below 1 Ω B11-1 (+B) - IG2 relay terminal 5 Always Below 1 Ω B10-1 (+B) - IG2 relay terminal 5 Always Below 1 Ω B9-1 (+B) - IG2 relay terminal 5 Always Below 1 Ω B12-1 (+B), B11-1 (+B), B10-1 (+B), B9-1 (+B) or IG2 relay terminal 5 - Body ground Always 10 kΩ or higher
Result:
OK
GO TO ECM POWER SOURCE CIRCUIT: ECM Power Source Circuit [12/2012 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR