Home >> Toyota >> 2015 >> RAV4 XLE, FWD >> Repair and Diagnosis >> Engine Performance >> Testing & Diagnosis >> SFI System [2AR-FE] (Diagnostic Codes) (Except Hybrid) (2 Of 7) >> SFI System >> DTC P2237-P2239, P2252, P2253; Oxygen (A/F) Sensor Pumping Current Circuit / Open (Bank 1 Sensor 1) [12/2012 - 08/2014] >> Description

DTC P2237-P2239, P2252, P2253; Oxygen (A/F) Sensor Pumping Current Circuit / Open (Bank 1 Sensor 1) [12/2012 - 08/2014]: Description

HINT: 

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P2237 Oxygen (A/F) Sensor Pumping Current Circuit / Open (Bank 1 Sensor 1) An open in the circuit between terminals A1A+ and A1A- of the air fuel ratio sensor while the engine is running (2 trip detection logic).
  • Open in air fuel ratio sensor (sensor 1) circuit
  • Air fuel ratio sensor (sensor 1)
  • ECM
Comes on DTC stored DTC for Mexico Models
- Applies
P2238 Oxygen (A/F) Sensor Pumping Current Circuit Low (Bank 1 Sensor 1)
  • Case 1

    Condition (a) or (b) continues for 5.0 seconds or more (2 trip detection logic):

    (a) Voltage at terminal A1A+ is 0.5 V or less.

    (b) Voltage difference between terminals A1A+ and A1A- is 0.1 V or less.

  • Case 2

    Air fuel ratio sensor admittance: Less than 0.0074 1/Ω (2 trip detection logic).

  • Open or short in air fuel ratio sensor (sensor 1) circuit
  • Air fuel ratio sensor (sensor 1)
  • ECM
Comes on DTC stored DTC for Mexico Models
- Applies
P2239 Oxygen (A/F) Sensor Pumping Current Circuit High (Bank 1 Sensor 1) The A1A+ voltage is higher than 4.5 V (2 trip detection logic).
  • Open or short in air fuel ratio sensor (sensor 1) circuit
  • Air fuel ratio sensor (sensor 1)
  • ECM
Comes on DTC stored DTC for Mexico Models
- Applies
P2252 Oxygen (A/F) Sensor Reference Ground Circuit Low (Bank 1 Sensor 1) The A1A- voltage is 0.5 V or less (2 trip detection logic).
  • Open or short in air fuel ratio sensor (sensor 1) circuit
  • Air fuel ratio sensor (sensor 1)
  • ECM
Comes on DTC stored DTC for Mexico Models
- Applies
P2253 Oxygen (A/F) Sensor Reference Ground Circuit High (Bank 1 Sensor 1) The A1A- voltage is higher than 4.5 V (2 trip detection logic).
  • Open or short in air fuel ratio sensor (sensor 1) circuit
  • Air fuel ratio sensor (sensor 1)
  • ECM
Comes on DTC stored DTC for Mexico Models