DTC P0A08-264: DC / DC Converter Status Circuit [11/2014 - ]: Procedure
- CHECK DTC OUTPUT (HYBRID CONTROL)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Check if DTCs are output.
Result
Result Proceed to DTC P0A08-264 only is output. A Any of the following DTCs including pending DTCs are also output. B DTC No. Relevant Diagnosis P0A1B-547 Drive Motor "A" Control Module P0A40-549 Drive Motor "A" Position Sensor Circuit Range/Performance P0A78-548 Drive Motor "A" Inverter Performance P0A93-346 Inverter Cooling System Performance P0AA6-526, 613 Hybrid Battery Voltage System Isolation Fault P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low P0AE6-225 Hybrid Battery Precharge Contactor Control Circuit Low P0C73-776 Motor Electronics Coolant Pump "A" Control Performance P3004-131, 803 Power Cable Malfunction P314A-828 Inverter Coolant Pump Speed Signal - Turn the power switch off.
B → See step 27
A: Go to next step
- CHECK FUSE (DC/DC-S)
- Remove the DC/DC-S fuse from the engine room relay block and junction block assembly.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition DC/DC-S fuse terminals Always Below 1 Ω TEXT IN ILLUSTRATION*1 Engine Room Relay Block and Junction Block Assembly *2 DC/DC-S Fuse - Install the DC/DC-S fuse.
NG → See step 24
OK: Go to next step
- Remove the DC/DC-S fuse from the engine room relay block and junction block assembly.
- CHECK FUSIBLE LINK (DC/DC)
- Disconnect connector 1E from the engine room relay block and junction block assembly.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 1F-1 (AMD) - 1E-1 Always Below 1 Ω - Check the fusible links (DC/DC) in the engine room relay block and junction block assembly for improper installation.
OK
The fusible link is installed securely.
- Connect the engine room relay block and junction block assembly connector.
NG → REPLACE FUSIBLE LINK BLOCK ASSEMBLY (FUSIBLE LINK(DC/DC))
OK: Go to next step
- Disconnect connector 1E from the engine room relay block and junction block assembly.
- CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR) See step 3
NG → CONNECT SECURELY
OK: Go to next step
- CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) See step 4
NG → CONNECT SECURELY
OK: Go to next step
- CHECK CABLE AND WIRE HARNESS WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
- Remove the inverter cover from the inverter with converter assembly.
- Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.NOTE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance
Tester Connection Switch Condition Specified Condition f3-1 (W) - Body ground and shield ground Power switch off 1 MΩ or higher f3-2 (U) - Body ground and shield ground Power switch off 1 MΩ or higher f3-3 (V) - Body ground and shield ground Power switch off 1 MΩ or higher e3-1 (W) - Body ground and shield ground Power switch off 1 MΩ or higher e3-2 (U) - Body ground and shield ground Power switch off 1 MΩ or higher e3-3 (V) - Body ground and shield ground Power switch off 1 MΩ or higher TEXT IN ILLUSTRATION*1 Three-phase AC Cable for MG1 *2 Three-phase AC Cable for MG2 HINT:
Perform this inspection while the three-phase AC cable for MG1 and for MG2 are connected.
- Install the inverter cover to the inverter with converter assembly.
NG → See step 16
OK: Go to next step
- Check that the service plug grip is not installed.
- CHECK ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY (AMD TERMINAL CONNECTION CONDITION) WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
- Check that the bolt for the AMD terminal is tightened to the specified torque, the AMD terminal is connected securely, and there is no contact problem.
Torque
T=8.3 N*m {85 kgf*cm, 73 in.*lbf }
Result
Result Proceed to There are no arc marks. The terminal is connected securely and there is no contact problem. A There are no arc marks. The terminal is not connected securely and there is a contact problem. B There are arc marks. - C
B → CONNECT SECURELY
C → REPLACE MALFUNCTIONING PARTS
A: Go to next step
- Check that the service plug grip is not installed.
- CHECK TERMINAL VOLTAGE (AMD TERMINAL VOLTAGE) WARNING:
Be sure to wear insulated gloves.
- Connect the cable to the negative (-) auxiliary battery terminal.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition 1F-1 (AMD) - Body ground Power switch off Same as auxiliary battery voltage
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY - INVERTER WITH CONVERTER) WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
- Disconnect connector A59 from the inverter with converter assembly.
- Connect the cable to the negative (-) auxiliary battery terminal.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition A59-11 (S) - Body ground Always Same as auxiliary battery voltage TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Inverter with Converter Assembly) - Disconnect the cable from the negative (-) auxiliary battery terminal.
- Connect the inverter with converter assembly connector.
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- Check that the service plug grip is not installed.
- CHECK POWER MANAGEMENT CONTROL ECU WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
- Disconnect connector A59 from the inverter with converter assembly.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition A59-12 (NODD) - Body ground Power switch off 110 to 150 kΩ TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Inverter with Converter Assembly) - Connect the inverter with converter assembly connector.
NG → See step 18
OK: Go to next step
- Check that the service plug grip is not installed.
- CHECK DC/DC CONVERTER FUNCTION
HINT:
The current at the AMD terminal cannot be measured directly because of space limitations. Measure the current flowing at the auxiliary battery instead.
- Connect the AC/DC 400 A probe to the positive auxiliary battery line.
- Install the service plug grip.
- Connect the cable to the negative (-) auxiliary battery terminal.
- Turn the power switch on (READY) and leave the vehicle as it is until the electric current flowing into the auxiliary battery becomes 10 A or less.
HINT:
If the power switch turns off immediately after it is turned on (READY), auxiliary battery voltage may be low. Recharge the auxiliary battery and perform this procedure again.
- Measure the current flowing from the auxiliary battery with the power switch on (READY), the headlight position switch and blower motor switch in the HI position, and the rear window defogger turned on.
Standard Current
Item Switch Condition Specified Condition Current flowing from auxiliary battery Power switch on (READY)
(The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.)0 A or less
(no current from auxiliary battery) - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Item Switch Condition Specified Condition Auxiliary battery voltage Power switch on (READY)
(The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.)13 to 15 V - Turn the power switch off.
NG → See step 30
OK: Go to next step
- CHECK QUANTITY OF HV COOLANT See step 3
B → ADD HV COOLANT
C → INSPECT FOR COOLANT LEAK AND ADD COOLANT
A: Go to next step
- CHECK COOLANT HOSE See step 4
NG → CORRECT THE PROBLEM
OK: Go to next step
- PERFORM ACTIVE TEST USING TECHSTREAM (CONTROL THE ELECTRIC COOLING FAN) See step 5
NG → See step 31
OK: Go to next step
- CHECK HV COOLANT (CHECK FOR CONDITIONS THAT MAY HAVE CAUSED FREEZING)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Read the freeze frame data Ambient Temperature using the Techstream.
- Check if the freeze frame data Ambient Temperature is below freezing.
Result
Result Proceed to Ambient Temperature value is above freezing temperature of the HV coolant A Ambient Temperature value is below freezing temperature of the HV coolant B HINT:
- HV coolant (SLLC) with a 30% concentration freezes at -15 °C (5°F) and HV coolant (SLLC) with a 50% concentration freezes at -35°C (-31°F).
- If the HV coolant freezes in the HV radiator or HV water pump, the coolant temperature in the inverter with converter assembly rises because the HV coolant cannot circulate. As a result, a DTC may be set.
- A DTC is set when the water pump impeller cannot rotate due to freezing of the HV coolant.
- If a DTC is set due to freezing of HV coolant, the problem cannot be reproduced. Judge whether freezing of HV coolant occurred according to the freeze point of the HV coolant, HV coolant change history and ambient temperature when the DTC was set.
- Turn the power switch off.
B → See step 19
A → See step 30
- CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1) WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
- Remove the inverter cover from the inverter with converter assembly.
- Disconnect the three-phase AC cables for MG1 from the inverter with converter assembly.TEXT IN ILLUSTRATION
*1 Three-phase AC Cables for MG1 - Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.NOTE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance
Tester Connection Switch Condition Specified Condition f3-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher f3-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher f3-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher TEXT IN ILLUSTRATION*1 Shield Ground *a Three-phase AC Cables for MG1 - Connect the three-phase AC cables for MG1 to the inverter with converter assembly.
- Install the inverter cover to the inverter with converter assembly.
NG → See step 20
OK: Go to next step
- Check that the service plug grip is not installed.
- CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2) WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
- Remove the inverter cover from the inverter with converter assembly.
- Disconnect the three-phase AC cables for MG2 from the inverter with converter assembly.TEXT IN ILLUSTRATION
*1 Three-phase AC Cables for MG2 - Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.NOTE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance
Tester Connection Switch Condition Specified Condition e3-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher e3-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher e3-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher TEXT IN ILLUSTRATION*1 Shield Ground *a Three-phase AC Cables for MG2 - Connect the three-phase AC cables for MG2 to the inverter with converter assembly.
- Install the inverter cover to the inverter with converter assembly.
NG → See step 22
OK → See step 30
- Check that the service plug grip is not installed.
- INSPECT POWER MANAGEMENT CONTROL ECU
- Disconnect all the connectors from the power management control ECU.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition A21-21 (NODD) - L5-6 (E1) Power switch off 110 to 150 kΩ TEXT IN ILLUSTRATION*a Component without harness connected
(Power Management Control ECU) - Connect the power management control ECU connectors.
NG → See step 29
OK → REPAIR OR REPLACE HARNESS OR CONNECTOR
- Disconnect all the connectors from the power management control ECU.
- REPLACE HV COOLANT See step 7
NEXT → COMPLETED
- CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION). Refer to PROCEDURE - Step 26
B → REPLACE MALFUNCTIONING PARTS
C → CONNECT SECURELY
A: Go to next step
- CHECK GENERATOR CABLE. Refer to PROCEDURE - Step 27
NG → See step 32
OK → See step 28
- CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE CONNECTION CONDITION). Refer to PROCEDURE - Step 28
B → REPLACE MALFUNCTIONING PARTS
C → CONNECT SECURELY
A: Go to next step
- CHECK MOTOR CABLE. Refer to PROCEDURE - Step 29
NG → See step 33
OK → See step 28
- CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - DC/DC-S FUSE) WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
- Disconnect connector A59 from the inverter with converter assembly.
- Remove the DC/DC-S fuse from the engine room relay block and junction block assembly.TEXT IN ILLUSTRATION
*1 Engine Room Relay Block and Junction Block Assembly *2 DC/DC-S Fuse - Measure the resistance according to the value(s) in the table below.TEXT IN ILLUSTRATION
*1 Engine Room Relay Block and Junction Block Assembly *2 DC/DC-S Fuse *a Front view of wire harness connector
(to Inverter with Converter Assembly)- - Standard Resistance
Tester Connection Switch Condition Specified Condition A59-11 (S) or 2 (DC/DC-S fuse) - Body ground and other terminals Power switch off 10 kΩ or higher - Install the DC/DC-S fuse.
- Connect the inverter with converter assembly connector.
NG → See step 26
OK: Go to next step
- Check that the service plug grip is not installed.
- REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS
Refer to DTC CHECK / CLEAR [11/2014 - ]
NEXT → REPLACE FUSE (DC/DC-S)
- REPAIR OR REPLACE HARNESS OR CONNECTOR
NEXT → REPLACE FUSE (DC/DC-S)
- GO TO DTC CHART (HYBRID CONTROL SYSTEM). Refer to DIAGNOSTIC TROUBLE CODE CHART [11/2014 - ]
- REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY. Refer to COMPONENTS [11/2014 - ]
- REPLACE POWER MANAGEMENT CONTROL ECU. Refer to COMPONENTS [11/2014 - ]
- REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS. Refer to DTC CHECK / CLEAR [11/2014 - ]
- CHECK COOLING FAN SYSTEM. Refer to Cooling Fan Circuit [11/2014 - ]
- REPLACE GENERATOR CABLE. Refer to COMPONENTS [11/2014 - ]
- REPLACE MOTOR CABLE. Refer to COMPONENTS [11/2014 - ]