Inspection [12/2013 - ]: Procedure
- INSPECT NO. 1 ROOM LIGHT ASSEMBLY
- Apply battery voltage to the connector and check that the No. 1 room light comes on.
*a Component without harness connected
(No. 1 Room Light Assembly)OK
Measurement Condition Condition Specified Condition Battery positive (+) → 2 (B)
Battery negative (-) → 1 (L)Always No. 1 room light comes on If the result is not as specified, replace the bulb or No. 1 room light assembly.
- Apply battery voltage to the connector and check that the No. 1 room light comes on.