SRS Warning Light does not Come ON [09/2014 - ]: Procedure
- CHECK AUXILIARY BATTERY VOLTAGE
- Measure the voltage of the auxiliary battery.
Standard Voltage
11 to 14 V
NG → See step 6
OK: Go to next step
- Measure the voltage of the auxiliary battery.
- CHECK CONNECTOR
- Turn the power switch off.
- Disconnect the cable from the negative (-) auxiliary battery terminal.WARNING:
Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.
- Check that the connector is properly connected to the combination meter assembly.
OK
The connector is properly connected.
HINT:
If the connector is not connected securely, reconnect the connector and proceed to the next inspection.
- Disconnect the connector from the combination meter assembly.
- Check that the terminal of the connector is not deformed or damaged.
OK
The terminal is not deformed or damaged.
NG → REPAIR OR REPLACE CONNECTOR
OK: Go to next step
- CHECK WIRE HARNESS (COMBINATION METER ASSEMBLY - BODY GROUND)
- Connect the cable to the negative (-) auxiliary battery terminal.
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition I18-13 (IG+) - Body ground Power switch on (IG) 11 to 14 V I18-1 (B) - Body ground Power switch off 11 to 14 V - Turn the power switch off.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition I18-20 (ES) - Body ground Always Below 1 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Combination Meter Assembly)
NG → REPAIR OR REPLACE WIRE HARNESS
OK: Go to next step
- Connect the cable to the negative (-) auxiliary battery terminal.
- CHECK SRS WARNING LIGHT
- Disconnect the cable from the negative (-) auxiliary battery terminal.WARNING:
Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.
- Connect the connector to the combination meter assembly.
- Disconnect the connector from the airbag sensor assembly.
- Connect the cable to the negative (-) auxiliary battery terminal.
- Turn the power switch on (IG) and check the SRS warning light condition.
OK
After the primary check period, the SRS warning light goes off for approximately 10 seconds and comes back on.
HINT:
The primary check period is approximately 6 seconds after the power switch is turned on (IG).
NG → See step 7
OK → See step 5
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- REPLACE AIRBAG SENSOR ASSEMBLY. Refer to REMOVAL [09/2014 - ]
- INSPECT CHARGING SYSTEM AND AUXILIARY BATTERY. Refer to ON-VEHICLE INSPECTION [09/2014 - ]
- REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [09/2014 - ]