Fuel Receiver Gauge Malfunction [09/2014 - ]: Procedure
- PERFORM ACTIVE TEST USING TECHSTREAM (FUEL METER OPERATION)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter following menus: Body Electrical / Combination Meter / Active Test.
- Perform the Active Test according to the display on the Techstream.COMBINATION METER
Tester Display Test Part Control Range Diagnostic Note Fuel Meter Operation Fuel receiver gauge OFF, Sender E, Empty, Warning, 1/4, 1/2, 3/4, Full, Sender F - OK
Fuel receiver gauge indication is normal.
NG → See step 5
OK: Go to next step
- READ VALUE USING TECHSTREAM (FUEL INPUT)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter following menus: Body Electrical / Combination Meter / Data List.
- Read the Data List according to the display on the Techstream.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Fuel Input Fuel input/Min.: 0, Max.: 127.5 Fuel receiver gauge indicates F: 57.9 Unit: Liter Fuel receiver gauge indicates 3/4: 45.6 Fuel receiver gauge indicates 1/2: 32.2 Fuel receiver gauge indicates 1/4: 18.9 Fuel receiver gauge indicates E: 6.4 Result
Result Proceed to Fuel level data displayed on the Techstream is almost the same as the fuel receiver gauge indication. A Fuel level data displayed on the Techstream differs from the fuel receiver gauge indication. B
B → See step 5
A: Go to next step
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - FUEL SENDER GAUGE ASSEMBLY)
- Disconnect the I18 combination meter assembly and N11 fuel sender gauge assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
w/o Multi-information Display:
w/ Multi-information Display:
Tester Connection Condition Specified Condition I18-18 (FR) - N11-2 (FS) Always Below 1 Ω I18-18 (FR) - Body ground Always 10 kΩ or higher I18-17 (FE) - N11-3 (FE) Always Below 1 Ω I18-17 (FE) - Body ground Always 10 kΩ or higher Tester Connection Condition Specified Condition I18-14 (FR) - N11-2 (FS) Always Below 1 Ω I18-14 (FR) - Body ground Always 10 kΩ or higher I18-15 (FE) - N11-3 (FE) Always Below 1 Ω I18-15 (FE) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- INSPECT FUEL SENDER GAUGE ASSEMBLY
- Remove the fuel sender gauge assembly. Refer to REMOVAL [09/2014 - ] for 2AR-FE. Refer to REMOVAL [09/2014 - ] for 2GR-FE).
- Inspect the fuel sender gauge assembly. Refer to INSPECTION [09/2014 - ]
for 2AR-FE. Refer to INSPECTION [09/2014 - ]
for 2GR-FE).
Result
Result Proceed to OK A NG (for 2AR-FE) B NG (for 2GR-FE) C
B → See step 6
C → See step 7
A → See step 5
- REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [09/2014 - ]
- REPLACE FUEL SENDER GAUGE ASSEMBLY. Refer to REMOVAL [09/2014 - ]
- REPLACE FUEL SENDER GAUGE ASSEMBLY. Refer to REMOVAL [09/2014 - ]