Entire Combination Meter does not Operate [09/2014 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)
- Disconnect the I18 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
w/o Multi-information Display
w/ Multi-information Display
Tester Connection Condition Specified Condition I18-7 (ES) - Body ground Always Below 1 Ω Tester Connection Condition Specified Condition I18-20 (ES) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition I18-13 (IG+) - Body ground Ignition switch off Below 1 V Ignition switch ON 11 to 14 V I18-1 (B) - Body ground Always 11 to 14 V TEXT IN ILLUSTRATION*A w/o Multi-information Display *B w/ Multi-information Display *a Front view of wire harness connector
(to Combination Meter Assembly)
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 2
- Disconnect the I18 combination meter assembly connector.
- REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [09/2014 - ]