Indicator Circuit [09/2014 - ]: Procedure
- PERFORM ACTIVE TEST USING TECHSTREAM (METER DISPLAY 1)
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Active Test.
- Perform Active Test according to the display on Techstream.COMBINATION METER
Tester Display Test Part Control Range Diagnostic Note Meter Display 1 Multi-information display OFF or All Confirm that the vehicle is stopped with the engine switch on (IG)
NG → See step 5
OK: Go to next step
- READ VALUE USING TECHSTREAM (LDA INDICATOR)
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Chassis / Lane Departure Alert / Data List.
- Read the Data List according to the display on the Techstream.LANE DEPARTURE ALERT
Tester Display Measurement Item/Range Normal Condition Diagnostic Note LDA Indicator Status of the lane departure alert indicator/Nothing or Green Nothing: Lane departure alert indicator is not illuminated
Green: Lane departure alert indicator is illuminated-
NG → See step 4
OK → See step 3
- PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [09/2014 - ]
- REPLACE LANE DEPARTURE WARNING CAMERA. Refer to REMOVAL [09/2014 - ]
- GO TO METER / GAUGE SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [09/2014 - ]