DTC P324E-788: MG-ECU Power Relay Intermittent Circuit [10/2014 - 10/2015]: Procedure
- CHECK DTC OUTPUT (HYBRID CONTROL)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Check for DTCs.
Result
Result Proceed to P324E-788 only is output. A U0110-159, 160, 656, 657 are also output. B - Turn the power switch off.
B
GO TO DTC CHART (HYBRID CONTROL SYSTEM)
(Refer to DIAGNOSTIC TROUBLE CODE CHART [10/2014 - 10/2015] )
A
See step 2
- CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Refer to PROCEDURE - Step 4
NG
CONNECT SECURELY
OK
See step 3
- CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT RELAY) WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless otherwise instructed because this may cause a malfunction.
- Disconnect the A50 inverter with converter assembly connector.
- Remove the IGCT relay from the No. 2 engine room relay block.
- Measure the resistance according to the value (s) in the table below.
*1 No. 2 Engine Room Relay Block *2 IGCT Relay *a Front view of wire harness connector
(to Inverter with Converter Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition A50-30 (+B) - 5 (IGCT relay) Power switch off Below 1 Ω A50-31 (+B2) - 5 (IGCT relay) Power switch off Below 1 Ω A50-10 (GND1) - Body ground Power switch off Below 1 Ω A50-11 (GND2) - Body ground Power switch off Below 1 Ω - Install the IGCT relay.
- Reconnect the A50 inverter with converter assembly connector.
OK
REPLACE INVERTER WITH CONVERTER ASSEMBLY
(Refer to COMPONENTS [10/2014 - ] )
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- Check that the service plug grip is not installed.