Home >> Toyota >> 2015 >> Avalon Hybrid Limited >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Testing and Diagnosis >> Hybrid Control System - Diagnostic Codes - (Hybrid) (2 Of 8) >> Hybrid Control System >> DTC P324E-788: MG-ECU Power Relay Intermittent Circuit [10/2014 - 10/2015] >> Procedure

DTC P324E-788: MG-ECU Power Relay Intermittent Circuit [10/2014 - 10/2015]: Procedure

  1. CHECK DTC OUTPUT (HYBRID CONTROL) 
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (IG).
    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
    4. Check for DTCs.

      Result

      Result Proceed to
      P324E-788 only is output. A
      U0110-159, 160, 656, 657 are also output. B
    5. Turn the power switch off.

    GO TO DTC CHART (HYBRID CONTROL SYSTEM) 

    (Refer to DIAGNOSTIC TROUBLE CODE CHART [10/2014 - 10/2015] )

    See step  2

  2. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) 

    Refer to PROCEDURE - Step 4

    NG 

    CONNECT SECURELY 

    OK 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT RELAY) 
    WARNING:

    Be sure to wear insulated gloves.

    1. Check that the service plug grip is not installed.
      NOTE:

      After removing the service plug grip, do not turn the power switch on (READY), unless otherwise instructed because this may cause a malfunction.

    2. Disconnect the A50 inverter with converter assembly connector.
    3. Remove the IGCT relay from the No. 2 engine room relay block.
    4. Measure the resistance according to the value (s) in the table below.
      GTY603217Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *1 No. 2 Engine Room Relay Block *2 IGCT Relay
      *a Front view of wire harness connector
      (to Inverter with Converter Assembly)
      - -

      Standard Resistance

      Tester Connection Condition Specified Condition
      A50-30 (+B) - 5 (IGCT relay) Power switch off Below 1 Ω
      A50-31 (+B2) - 5 (IGCT relay) Power switch off Below 1 Ω
      A50-10 (GND1) - Body ground Power switch off Below 1 Ω
      A50-11 (GND2) - Body ground Power switch off Below 1 Ω
    5. Install the IGCT relay.
    6. Reconnect the A50 inverter with converter assembly connector.

    OK 

    REPLACE INVERTER WITH CONVERTER ASSEMBLY 

    (Refer to COMPONENTS [10/2014 - ] )

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR