DTC B14AA: Glass Humidity Sensor Circuit [10/2014 - ]: Procedure
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Data List.
- Check the value(s) by referring to the table below.AIR CONDITIONER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Glass Humidity Glass humidity /
Min.: 0.00%, Max.: 100.00%Actual glass humidity displayed - OK
The display is as specified in the normal condition column.
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
(Refer to REMOVAL [10/2014 - ] )
Result:
NG
See step 2
- INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
- Disconnect the N3 air conditioning thermistor assembly (glass humidity sensor) connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition N3-5 (S5V) - Body ground Power switch on (IG) 4.5 to 5.5 V TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Air Conditioning Thermistor Assembly (Glass Humidity Sensor))
Result:
NG
See step 5
Result:
OK
See step 3
- Disconnect the N3 air conditioning thermistor assembly (glass humidity sensor) connector.
- INSPECT AIR CONDITIONING THERMISTOR ASSEMBLY (GLASS HUMIDITY SENSOR)
- Remove the air conditioning thermistor assembly (glass humidity sensor) with the connector still connected.
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 1 (SEG3) - 3 (RH) Humidity is 5 to 15% 1.01 V 1 (SEG3) - 3 (RH) Humidity is 15 to 25% 1.37 V 1 (SEG3) - 3 (RH) Humidity is 25 to 35% 1.73 V 1 (SEG3) - 3 (RH) Humidity is 35 to 45% 2.09 V 1 (SEG3) - 3 (RH) Humidity is 45 to 55% 2.45 V 1 (SEG3) - 3 (RH) Humidity is 55 to 65% 2.81 V 1 (SEG3) - 3 (RH) Humidity is 65 to 75% 3.17 V 1 (SEG3) - 3 (RH) Humidity is 75 to 85% 3.53 V 1 (SEG3) - 3 (RH) Humidity is 85 to 95% 3.89 V NOTE:- Do not touch the sensor as body heat will affect the inspection results. When performing the inspection, hold the sensor by its connector.
- Allow the sensor to acclimate to the ambient temperature and humidity before performing the inspection.
- The specified voltages in the table above are based on inspections performed when the ambient temperature is 25°C (77°F).
HINT:
As the humidity increases, the voltage increases (see the graph).
TEXT IN ILLUSTRATION*a Component with harness connected
(Air Conditioning Thermistor Assembly (Glass Humidity Sensor))*b Heat Conduction Sheet Part *c Voltage (V) *d Relative Humidity (%)
Result:
NG
REPLACE AIR CONDITIONING THERMISTOR ASSEMBLY
(Refer to REMOVAL [10/2014 - ] )
Result:
OK
See step 4
- Remove the air conditioning thermistor assembly (glass humidity sensor) with the connector still connected.
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING THERMISTOR ASSEMBLY (GLASS HUMIDITY SENSOR) - AIR CONDITIONING AMPLIFIER)
- Disconnect the N3 air conditioning thermistor assembly (glass humidity sensor) connector.
- Disconnect the D62 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition N3-3 (RH) - D62-28 (RH) Always Below 1 Ω N3-3 (RH) - Body ground Always 10 kΩ or higher N3-1 (SEG3) - D62-35 (SG-4) Always Below 1 Ω N3-1 (SEG3) - Body ground Always 10 kΩ or higher
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
(Refer to REMOVAL [10/2014 - ] )
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING THERMISTOR ASSEMBLY (GLASS HUMIDITY SENSOR) - AIR CONDITIONING AMPLIFIER)
- Disconnect the D62 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition N3-5 (S5V) - D62-31 (S5-4) Always Below 1 Ω N3-5 (S5V) - Body ground Always 10 kΩ or higher
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
(Refer to REMOVAL [10/2014 - ] )
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR