DTC B1413/13: Evaporator Temperature Sensor Circuit [10/2014 - ]: Procedure
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Data List.
- Check the value(s) by referring to the table below.AIR CONDITIONER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Evaporator Fin Thermistor No. 1 cooler thermistor /
Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)Actual evaporator temperature displayed - OK
The display is as specified in the normal condition column.
Result
Result Proceed to NG A OK (When troubleshooting according to Problem Symptoms Table) B OK (When troubleshooting according to the DTC) C
Result:
B
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE
(Refer to PROBLEM SYMPTOMS TABLE [10/2014 - 10/2015] or PROBLEM SYMPTOMS TABLE [10/2015 - ] )
Result:
C
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
(Refer to REMOVAL [10/2014 - ] )
Result:
A
See step 2
- INSPECT NO. 1 COOLER THERMISTOR
- Remove the No. 1 cooler thermistor (Refer to REMOVAL [10/2014 - ]
).TEXT IN ILLUSTRATION
*a Component without harness connected
(No. 1 Cooler Thermistor)*b Sensing Portion *c Resistance (kΩ) *d Allowable Range *e Temperature (°C (°F)) - - - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 -10°C (14°F) 7.30 to 9.10 kΩ 1 - 2 -5°C (23°F) 5.65 to 6.95 kΩ 1 - 2 0°C (32°F) 4.40 to 5.35 kΩ 1 - 2 5°C (41°F) 3.40 to 4.15 kΩ 1 - 2 10°C (50°F) 2.70 to 3.25 kΩ 1 - 2 15°C (59°F) 2.14 to 2.58 kΩ 1 - 2 20°C (68°F) 1.71 to 2.05 kΩ 1 - 2 25°C (77°F) 1.38 to 1.64 kΩ 1 - 2 30°C (86°F) 1.11 to 1.32 kΩ NOTE:- Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
- When measuring, the sensor temperature must be the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see the graph).
Result:
NG
REPLACE NO. 1 COOLER THERMISTOR
(Refer to REMOVAL [10/2014 - ] )
Result:
OK
See step 3
- Remove the No. 1 cooler thermistor (Refer to REMOVAL [10/2014 - ]
).
- INSPECT AIR CONDITIONING HARNESS ASSEMBLY
- Remove the air conditioning harness assembly (Refer to REMOVAL [10/2014 - 10/2015]
or REMOVAL [10/2015 - ]
).
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition z1-6 (TEA) - ae-2 Always Below 1 Ω z1-5 (SGA) - ae-1 Always Below 1 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Air Conditioning Amplifier Assembly)*b Front view of wire harness connector
(to No. 1 Cooler Thermistor)
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
(Refer to REMOVAL [10/2014 - ] )
Result:
NG
REPLACE AIR CONDITIONING HARNESS ASSEMBLY
(Refer to REMOVAL [10/2014 - 10/2015] or REMOVAL [10/2015 - ] )
- Remove the air conditioning harness assembly (Refer to REMOVAL [10/2014 - 10/2015]
or REMOVAL [10/2015 - ]
).