DTC B1411/11: Room Temperature Sensor Circuit [10/2014 - ]: Procedure
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Data List.
- Check the value(s) by referring to the table below.AIR CONDITIONER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Room Temperature Sensor Cooler (room temp. sensor) thermistor /
Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)Actual cabin temperature displayed - OK
The display is as specified in the normal condition column.
Result
Result Proceed to NG A OK (When troubleshooting according to Problem Symptoms Table) B OK (When troubleshooting according to the DTC) C
Result:
B
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE
(Refer to PROBLEM SYMPTOMS TABLE [10/2014 - 10/2015] or PROBLEM SYMPTOMS TABLE [10/2015 - ] )
Result:
C
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
(Refer to REMOVAL [10/2014 - ] )
Result:
A
See step 2
- INSPECT COOLER (ROOM TEMP. SENSOR) THERMISTOR
- Remove the cooler (room temp. sensor) thermistor (Refer to REMOVAL [10/2014 - ]
).
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 (+) - 2 (-) 10°C (50°F) 3.00 to 3.73 kΩ 1 (+) - 2 (-) 15°C (59°F) 2.45 to 2.88 kΩ 1 (+) - 2 (-) 20°C (68°F) 1.95 to 2.30 kΩ 1 (+) - 2 (-) 25°C (77°F) 1.60 to 1.80 kΩ 1 (+) - 2 (-) 30°C (86°F) 1.28 to 1.47 kΩ 1 (+) - 2 (-) 35°C (95°F) 1.00 to 1.22 kΩ 1 (+) - 2 (-) 40°C (104°F) 0.80 to 1.00 kΩ 1 (+) - 2 (-) 45°C (113°F) 0.65 to 0.85 kΩ 1 (+) - 2 (-) 50°C (122°F) 0.50 to 0.70 kΩ 1 (+) - 2 (-) 55°C (131°F) 0.44 to 0.60 kΩ 1 (+) - 2 (-) 60°C (140°F) 0.36 to 0.50 kΩ NOTE:- Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
- When measuring, the sensor temperature must be the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see the graph).
TEXT IN ILLUSTRATION*a Component without harness connected
(Cooler (Room Temp. Sensor) Thermistor)*b Sensing Portion *c Resistance (kΩ) *d Allowable Range *e Temperature (°C (°F))
Result:
NG
REPLACE COOLER (ROOM TEMP. SENSOR) THERMISTOR
(Refer to REMOVAL [10/2014 - ] )
Result:
OK
See step 3
- Remove the cooler (room temp. sensor) thermistor (Refer to REMOVAL [10/2014 - ]
).
- CHECK HARNESS AND CONNECTOR (COOLER (ROOM TEMP. SENSOR) THERMISTOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the D62 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition D62-29 (TR) - D45-1 (+) Always Below 1 Ω D62-34 (SG-1) - D45-2 (-) Always Below 1 Ω D62-29 (TR) - Body ground Always 10 kΩ or higher D62-34 (SG-1) - Body ground Always 10 kΩ or higher
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
(Refer to REMOVAL [10/2014 - ] )
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR