Home >> Toyota >> 2015 >> Avalon Hybrid Limited >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning System - Diagnostic Codes & Circuit Tests - (Hybrid) >> Air Conditioning System >> DTC B1411/11: Room Temperature Sensor Circuit [10/2014 - ] >> Description

DTC B1411/11: Room Temperature Sensor Circuit [10/2014 - ]: Description

The cooler (room temp. sensor) thermistor is installed in the instrument panel to detect the cabin temperature which is used to control the air conditioning system AUTO mode. The resistance of the cooler (room temp. sensor) thermistor changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the cooler (room temp. sensor) thermistor and reads voltage changes due to changes in the resistance of the cooler (room temp. sensor) thermistor.

DTC No. DTC Detection Condition Trouble Area
B1411/11 Open or short in cooler (room temp. sensor) thermistor circuit
  • Cooler (room temp. sensor) thermistor
  • Harness or connector between cooler (room temp. sensor) thermistor and air conditioning amplifier assembly
  • Air conditioning amplifier assembly