Mil Circuit [10/2014 - 10/2015]: Procedure
- Check That Mil Is Illuminated
- Perform Troubleshooting In Accordance With The Table Below.Result
Result Proceed To Mil Remains On A Mil Does Not Illuminate B
Result:
B
See Step 5
Result:
A
See Step 2
- Perform Troubleshooting In Accordance With The Table Below.
- Check Whether DTC Output Recurs
- Connect The Techstream To The Dlc3.
- Turn The Power Switch On (Ig).
- Turn The Techstream On.
- Enter The Following Menus: Powertrain / Engine And ECT / Trouble Codes.
- Check If Any DTCs Have Been Detected. Note Down Any DTCs.Result
Result Proceed To DTCs Are Not Output A DTCs Are Output B Hint:
Check For Detected DTCs Output From Other ECU's Which Relate To The Mil.
Result:
B
Repair Circuits Indicated By Output DTCs
Result:
A
See Step 3
- Check Harness And Connector (Check For Short In Wire Harness)
- Disconnect The A18 ECM Connector.
- Turn The Power Switch On (Ig).
- Check That The Mil Is Not Illuminated.
Ok
Mil Is Not Illuminated.
Text In Illustration*A Front View Of Wire Harness Connector
(To ECM)
Result:
Ok
Replace ECM
(Refer to Removal [10/2014 - ] )
Result:
Ng
See Step 4
- Disconnect The A18 ECM Connector.
- Check Harness And Connector (ECM - Combination Meter Assembly)
- Disconnect The Combination Meter Assembly Connector.
- Disconnect The ECM Connector.
- Measure The Resistance According To The Value(S) In The Table Below.
Standard Resistance
Tester Connection Condition Specified Condition A18-30 (W) Or D9-22 (CHK) - Body Ground Always 10 KΩ Or Higher
Result:
Ok
Replace Combination Meter Assembly
(Refer to Removal [10/2014 - ] )
Result:
Ng
Repair Or Replace Harness Or Connector
- Check That Mil Is Illuminated
- Check If The Mil Is Illuminated When The Power Switch Is Turned On (Ig).
Ok
Mil Should Be Illuminated.
Result:
Ok
Check For Intermittent Problems
(Refer to Check For Intermittent Problems [10/2014 - ] )
Result:
Ng
See Step 6
- Check If The Mil Is Illuminated When The Power Switch Is Turned On (Ig).
- Check That Engine Starts
- Connect The Techstream To The Dlc3.
- Turn The Power Switch On (Ig).
- Turn The Techstream On.
- Put The Engine In Inspection Mode (Maintenance Mode) (Refer to Inspection Mode Procedure [10/2014 - ] ).
- Start The Engine.Result
Result Proceed To Engine Starts A Engine Does Not Start* B Hint:
*: The Techstream Cannot Communicate With The ECM.
Result:
B
Go To VC Output Circuit
(Refer to VC Output Circuit [10/2014 - ] )
Result:
A
See Step 7
- Check Harness And Connector (Combination Meter Assembly - ECM)
- Disconnect The Combination Meter Assembly Connector.
- Disconnect The ECM Connector.
- Measure The Resistance According To The Value(S) In The Table Below.
Standard Resistance
Tester Connection Condition Specified Condition A18-30 (W) - D9-22 (CHK) Always Below 1 Ω
Result:
Ok
Replace Combination Meter Assembly
(Refer to Removal [10/2014 - ] )
Result:
Ng
Repair Or Replace Harness Or Connector