  1. INSPECT MOBILE WIRELESS CHARGER SWITCH 
    1. Measure the resistance according to the value(s) in the table below.
      GTY539457Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard Resistance

      Tester Connection Condition Specified Condition
      11 (+B) - 8 (D) Mobile wireless charger switch is on (not protruding) Below 1 Ω
      Mobile wireless charger switch is off (protruding) 10 kΩ or higher
      TEXT IN ILLUSTRATION

      *a Component without harness connected
      (Mobile Wireless Charger Switch)

      If the result is not as specified, replace the mobile wireless charger switch.

    2. Check that the switch indicator light illuminates.
      1. Apply auxiliary battery voltage to the mobile wireless charger switch connector and check the operation of the switch indicator light.
        GTY473612Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

        OK

        Connection Condition Specified Condition
        Auxiliary battery positive (+) → Terminal 11 (+B)
        Auxiliary battery negative (-) → Terminal 12 (E)
        Mobile wireless charger switch is on (not protruding) Switch indicator light illuminates
        Mobile wireless charger switch is off (protruding) Switch indicator light does not illuminate
        TEXT IN ILLUSTRATION

        *a Component without harness connected
        (Mobile Wireless Charger Switch)

        If the result is not as specified, replace the mobile wireless charger switch.

    3. Check that the switch illuminates.
      1. Apply auxiliary battery voltage to the mobile wireless charger switch and check that the switch illuminates.
        GTY539475Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

        OK

        Connection Specified Condition
        Auxiliary battery positive (+) → Terminal 10 (ILL+)
        Auxiliary battery negative (-) → Terminal 9 (ILL-)
        Illuminates
        TEXT IN ILLUSTRATION

        *a Component without harness connected
        (Mobile Wireless Charger Switch)

        If the result is not as specified, replace the mobile wireless charger switch.