Inspection [10/2014 - ]: Procedure
- INSPECT SEAT HEATER ASSEMBLY (FOR LH SIDE SEATBACK)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition J28-1 - D-1 Always Below 1 Ω J28-2 - D-2 15 to 30 °C (59 to86 °F) 3.88 to 4.75 Ω J28-2 - D-3 Always Below 1 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Seat Heater Assembly (for LH Side Seatback))If the result is not as specified, replace the seat heater assembly (for LH side seatback).
- Measure the resistance according to the value(s) in the table below.
- INSPECT SEAT HEATER ASSEMBLY (FOR RH SIDE SEATBACK)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition K11-1 - B-1 Always Below 1 Ω K11-2 - B-2 15 to 30 °C (59 to86 °F) 3.88 to 4.75 Ω K11-2 - B-3 Always Below 1 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Seat Heater Assembly (for RH Side Seatback))If the result is not as specified, replace the seat heater assembly (for RH side seatback).
- Measure the resistance according to the value(s) in the table below.