Inspection [10/2014 - ]: Procedure
- INSPECT FRONT LUMBAR POWER SEAT SWITCH (FOR DRIVER)
- w/ Memory
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 Down switch pressed Below 1 Ω 3 - 5 1 - 5 Up switch pressed 2 - 3 2 - 6 Hold switch pressed 4 - 5 2 - 4 Release switch pressed 5 - 6 1 - 2 Off 2 - 3 2 - 4 2 - 6 TEXT IN ILLUSTRATION*1 Up Switch *2 Down Switch *3 Hold Switch *4 Release Switch *a Component without harness connected
(Front Lumbar Power Seat Switch (for Driver))If the result is not as specified, replace the front lumbar power seat switch (for Driver).
- Measure the resistance according to the value(s) in the table below.
- w/o Memory
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 Hold switch pressed Below 1 Ω 3 - 5 1 - 5 Release switch pressed 2 - 3 2 - 6 Up switch pressed 4 - 5 2 - 4 Down switch pressed 5 - 6 1 - 2 Off 2 - 3 2 - 4 2 - 6 TEXT IN ILLUSTRATION*1 Up Switch *2 Down Switch *3 Hold Switch *4 Release Switch *a Component without harness connected
(Front Lumbar Power Seat Switch (for Driver))If the result is not as specified, replace the front lumbar power seat switch (for Driver).
- Measure the resistance according to the value(s) in the table below.
- w/ Memory
- INSPECT FRONT LUMBAR POWER SEAT SWITCH (FOR FRONT PASSENGER)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 Hold switch pressed Below 1 Ω 3 - 5 1 - 2 Off 2 - 3 1 - 5 Release switch pressed 2 - 3 TEXT IN ILLUSTRATION*1 Release Switch *2 Hold Switch *a Component without harness connected
(Front Lumbar Power Seat Switch (for Front Passenger))If the result is not as specified, replace the front lumbar power seat switch (for front passenger).
- Measure the resistance according to the value(s) in the table below.