Inspection [10/2014 - ]: Procedure
- INSPECT FRONT SEATBACK HEATER ASSEMBLY LH
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 15 to 30 °C (59 to86 °F) 3.26 to 3.99 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Front Seatback Heater Assembly LH)If the result is not as specified, replace the front seatback heater assembly LH
- Measure the resistance according to the value(s) in the table below.
- INSPECT FRONT SEATBACK HEATER ASSEMBLY RH
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 15 to 30 °C (59 to86 °F) 3.26 to 3.99 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Front Seatback Heater Assembly RH)If the result is not as specified, replace the front seatback heater assembly RH
- Measure the resistance according to the value(s) in the table below.