Inspection [10/2014 - ]: Procedure
- INSPECT ROOF CONSOLE BOX ASSEMBLY
- Inspect the front interior light.
- Connect a positive (+) lead from the auxiliary battery to terminal 9 (B) and a negative (-) lead to terminal 1 (GND) or 6 (CTY).
Result
Tester Connection Condition Specified Condition 9 (B) - 1 (GND) Interior light on/off switch off and interior light switches off Front interior light LH and RH do not come on Interior light on/off switch off and interior light switch LH on Front interior light LH comes on Interior light on/off switch off and interior light switch RH on Front interior light RH comes on Interior light on/off switch on and interior light switches off Front interior light LH and RH come on 9 (B) - 6 (CTY) Interior light door switch off and interior light switches off Front interior light LH and RH do not come on Interior light door switch off and interior light switches on Front interior light LH and RH do not come on Interior light door switch on and interior light switches off Front interior light LH and RH come on TEXT IN ILLUSTRATION*A w/ Ambient Light *a Component without harness connected
(Roof Console Box Assembly)If the result is not as specified, replace the bulb or roof console box assembly.
- Connect a positive (+) lead from the auxiliary battery to terminal 9 (B) and a negative (-) lead to terminal 1 (GND) or 6 (CTY).
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 (GND) - 10 (RRMP) Interior light switches off and interior light on/off switch off 10 kΩ or higher Interior light switches off and interior light on/off switch on Below 1 Ω 6 (CTY) - 10 (RRMP) Interior light door switch off 10 kΩ or higher Interior light door switch on Below 1 Ω 11 (+B1) - 1 (GND)*1 Mood switch on Below 1 Ω Mood switch off 10 kΩ or higher - *1: w/ Ambient Light
If the result is not as specified, replace the roof console box assembly.
- Inspect the front interior light.