Inspection [10/2014 - ]: Procedure
- INSPECT AUTOMATIC LIGHT CONTROL SENSOR
- Disconnect the D51 automatic light control sensor connector.
- Measure the voltage and resistance according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition D51-6 (CLTB) - D51-3 (CLTE) Power switch off Below 1 V Power switch on (IG) 11 to 14 V Standard Resistance
Tester Connection Condition Specified Condition D51-3 (CLTE) - Body ground Always Below 1 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Automatic Light Control Sensor)If the result is not as specified, there may be a malfunction on the wire harness side.
- Reconnect the D51 automatic light control sensor connector.
- Connect an oscilloscope to the automatic light control sensor connector.TEXT IN ILLUSTRATION
*a Component with harness connected
(Automatic Light Control Sensor) - Check the waveform.
OK
Tester Connection Tool Setting Condition Specified Condition D51-3 (CLTE) - D51-5 (CLTS) 5 V/DIV., 5 ms./DIV Power switch on (IG), light control switch in AUTO position Correct waveform is as shown HINT:
If the ambient light becomes brighter, width A becomes narrower.
If the result is not as specified, the automatic light control sensor may be malfunctioning.
- Disconnect the D51 automatic light control sensor connector.