LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2015 >> Avalon Hybrid Limited >> Repair and Diagnosis >> Accessories & Equipment >> Exterior Lights >> Automatic Headlight Beam Level Control System - Diagnostic Codes & Circuit Tests - (Hybrid) >> Automatic Headlight Beam Level Control System >> Circuit Tests >> Headlight Beam Level Control Actuator Circuit [10/2014 - ] >> Procedure

Headlight Beam Level Control Actuator Circuit [10/2014 - ]: Procedure

  1. PERFORM ACTIVE TEST USING TECHSTREAM 
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (READY).
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / HL Auto Leveling / Active Test.
    5. Check that the leveling motors operate.
      HL AUTO LEVELING

      Tester Display Test Part Control Range Diagnostic Note
      Drive The Leveling Motor UP Leveling motor upward operation ON/OFF ON: Moves up
      OFF: Stops
      Drive The Leveling Motor DOWN Leveling motor downward operation ON/OFF ON: Moves down
      OFF: Stops

      OK

      Headlight leveling motors operate normally.

    Result: 

    OK 

    PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE 

    (Refer to PROBLEM SYMPTOMS TABLE [10/2014 - ] )

    Result: 

    NG 

    See step  2

  2. CHECK HARNESS AND CONNECTOR (HEADLIGHT UNIT - HEADLIGHT LEVELING ECU ASSEMBLY) 
    1. Disconnect the A24 headlight leveling ECU assembly connector.
    2. Disconnect the A12 headlight unit LH connector or A39 headlight unit RH connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      FOR LH SIDE:

      Tester Connection Condition Specified Condition
      A24-18 (LHE) - A12-2 (LHM+) Always Below 1 Ω
      A24-11 (LH+) - A12-3 (LHB1) Always Below 1 Ω
      A24-24 (LH-) - A12-1 (LH E) Always Below 1 Ω
      A24-18 (LHE) - Body ground Always 10 kΩ or higher
      A24-11 (LH+) - Body ground Always 10 kΩ or higher
      A24-24 (LH-) - Body ground Always 10 kΩ or higher
      FOR RH SIDE:

      Tester Connection Condition Specified Condition
      A24-17 (RHE) - A39-2 (RHM+) Always Below 1 Ω
      A24-10 (RH+) - A39-3 (RHB1) Always Below 1 Ω
      A24-23 (RH-) - A39-1 (RH E) Always Below 1 Ω
      A24-17 (RHE) - Body ground Always 10 kΩ or higher
      A24-10 (RH+) - Body ground Always 10 kΩ or higher
      A24-23 (RH-) - Body ground Always 10 kΩ or higher

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR 

    Result: 

    OK 

    See step  3

  3. CHECK HEADLIGHT UNIT (HEADLIGHT LEVELING MOTOR) 
    1. Replace the headlight unit with a new or known good one (Refer to REMOVAL [10/2014 - 10/2015] or REMOVAL [10/2015 - ] ).
    2. Perform the Active Test of the leveling motors.

      OK

      Headlight leveling motors operate normally.

    Result: 

    OK 

    END (HEADLIGHT LEVELING MOTOR WAS DEFECTIVE) 

    Result: 

    NG 

    REPLACE HEADLIGHT LEVELING ECU ASSEMBLY 

    (Refer to REMOVAL [10/2014 - ] )