Power Source Circuit [10/2014 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - AUXILIARY BATTERY)
- Disconnect the O10 blind spot monitor sensor LH connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition O10-5 (BLB) - Body ground Power switch on (IG) 11 to 14 V Power switch off Below 1 V
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 2
- CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - BODY GROUND)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition O10-10 (BLGD) - Body ground Always Below 1 Ω
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 3
- Measure the resistance according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - AUXILIARY BATTERY)
- Disconnect the O12 blind spot monitor sensor RH connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition O12-5 (BRB) - Body ground Power switch on (IG) 11 to 14 V Power switch off Below 1 V
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - BODY GROUND)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition O12-10 (BRGD) - Body ground Always Below 1 Ω
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE
(Refer to PROBLEM SYMPTOMS TABLE [10/2014 - ] )
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- Measure the resistance according to the value(s) in the table below.