DTC B2250: Back Door Closer Operation Malfunction [12/2012 - 10/2015]: Procedure
- READ VALUE USING TECHSTREAM
- Check the Data List for proper functioning of the sector switch.
Refer to DATA LIST / ACTIVE TEST [12/2012 - 10/2015]
Body Electrical > Back Door > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Closer Position SW Sector switch signal ON or OFF ON: Back door lock center gear in center position
OFF: Back door lock center gear not in center position- Body Electrical > Back Door > Data List
Tester Display Closer Position SW OK
The display is as specified in the normal condition column.
Result:
OK
REPLACE MULTIPLEX NETWORK DOOR ECU: REMOVAL [12/2012 - 10/2015]
Result:
NG
See step 2
- Check the Data List for proper functioning of the sector switch.
- INSPECT BACK DOOR LOCK ASSEMBLY
- Remove the back door lock assembly.
Refer to REMOVAL [12/2012 - 10/2015]
- Inspect the back door lock assembly.
Refer to INSPECTION [12/2012 - 10/2015]
Result:
NG
REPLACE BACK DOOR LOCK ASSEMBLY: REMOVAL [12/2012 - 10/2015]
Result:
OK
See step 3
- Remove the back door lock assembly.
- CHECK HARNESS AND CONNECTOR (BACK DOOR LOCK ASSEMBLY - MULTIPLEX NETWORK DOOR ECU AND BODY GROUND)
- Disconnect the U13 back door lock assembly connector.
- Disconnect the U18 multiplex network door ECU connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition U13-6 (OPN) - U18-24 (POS) Always Below 1 Ω U13-4 (E) - Body ground Always Below 1 Ω U13-6 (OPN) or U18-24 (POS) - Body ground Always 10 kΩ or higher
Result:
OK
REPLACE MULTIPLEX NETWORK DOOR ECU: REMOVAL [12/2012 - 10/2015]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR