Removal [12/2013 - ]
- PRECAUTION NOTE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work. Refer to PRECAUTION [12/2013 - ] .
- REMOVE FRONT FLOOR COVER RH . Refer to REMOVAL [12/2013 - ] - Step 3
- DISCONNECT CABLE FROM AUXILIARY BATTERY NEGATIVE TERMINAL NOTE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected. Refer to INITIALIZATION [12/2013 - ] .
- REMOVE CENTER INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY . Refer to REMOVAL [12/2013 - ] - Step 4
- REMOVE NO. 2 INSTRUMENT PANEL REGISTER ASSEMBLY . Refer to REMOVAL [12/2013 - ] - Step 5
- REMOVE INSTRUMENT CLUSTER FINISH PANEL GARNISH . Refer to REMOVAL [12/2013 - ] - Step 6
- REMOVE CENTER INSTRUMENT PANEL REGISTER ASSEMBLY . Refer to REMOVAL [12/2013 - ] - Step 7
- REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY . Refer to REMOVAL [12/2013 - ] - Step 8
- REMOVE COMBINATION METER ASSEMBLY
- Remove the 2 screws.
- Disengage the 3 clips as shown in the illustration.
- Disconnect the 2 connectors.