LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2014 >> Highlander XLE, FWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 96 (SFI System [2GR-FXE] - Diagnostic Codes - (Hybrid) (1 Of 3)) >> SFI System >> DTC P0403: Exhaust Gas Recirculation Control Circuit [02/2014 - 11/2016] >> Typical Malfunction Thresholds

Typical Malfunction Thresholds

WARNING: This page is about a different variant/trim than selected.
One of the following conditions is met Conditions A, B, C or D
A. All of the following conditions are met -
EGR1 output terminal voltage Low
Either of the following conditions is met 1 or 2
1. Step motor Driving
2. EGR1 Not operating
B. All of the following conditions are met -
EGR2 output terminal voltage Low
Either of the following conditions is met 3 or 4
3. Step motor Driving
4. EGR2 Not operating
C. All of the following conditions are met -
EGR3 output terminal voltage Low
Either of the following conditions is met 5 or 6
5. Step motor Driving
6. EGR3 Not operating
D. All of the following conditions are met -
EGR4 output terminal voltage Low
Either of the following conditions is met 7 or 8
7. Step motor Driving
8. EGR4 Not operating