DTC P2716: Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) [11/2015 - 11/2016]: Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SLT CIRCUIT)
- Disconnect the ECM connector.
*a Front view of wire harness connector
(to ECM) - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition C1-15 (SLT+) - C1-14 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω C1-15 (SLT+) - Body ground and other terminals Always 10 kΩ or higher C1-14 (SLT-) - Body ground and other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result: 1
OK
REPLACE ECM. Refer to COMPONENTS [12/2013 - 11/2016]
Result: 2
NG
See step 2
- Disconnect the ECM connector.
- CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR)
- Disconnect the connector from the wiring harness connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition C1-15 (SLT+) - C2-15 (SLT+) Always Below 1 Ω C1-14 (SLT-) - C2-7 (SLT-) Always Below 1 Ω C1-15 (SLT+) or C2-15 (SLT+) - Body ground and other terminals Always 10 kΩ or higher C1-14 (SLT-) or C2-7 (SLT-) - Body ground and other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 3
- INSPECT TRANSMISSION WIRE (SLT)
- Remove the wiring harness connector from the transaxle.
*a Component without harness connected
(Transmission Wire) - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A-12 (SLT+) - A-7 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω A-12 (SLT+) - Body ground and other terminals Always 10 kΩ or higher A-7 (SLT-) - Body ground and other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result: 1
OK
REPLACE WIRING HARNESS CONNECTOR. Refer to COMPONENTS [12/2013 - 11/2016]
Result: 2
NG
See step 4
- Remove the wiring harness connector from the transaxle.
- INSPECT SHIFT SOLENOID VALVE SLT
- Remove shift solenoid valve SLT.
*1 Shift Solenoid Valve SLT - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω - Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.
OK
Valve moves and makes an operating sound.
Result
Proceed to OK NG
Result: 1
OK
REPLACE TRANSMISSION WIRE. Refer to COMPONENTS [12/2013 - ]
Result: 2
NG
REPLACE SHIFT SOLENOID VALVE SLT. Refer to COMPONENTS [08/2014 - 11/2016]
- Remove shift solenoid valve SLT.