ACC Signal Circuit [11/2016 - ]: Procedure
- CONFIRM MODEL
- Choose the model to be inspected.
Result
Result Proceed to w/ Smart Key System A w/o Smart Key System B
Result: 2
B
See step 6
Result: 1
A
See step 2
- Choose the model to be inspected.
- CHECK FOR DTC (SMART KEY SYSTEM (for Start Function))
- Clear the DTCs.
Refer to DTC CHECK / CLEAR [12/2013 - ]
Body Electrical > Power Source Control > Clear DTCs
- Check for the DTCs.
Refer to DTC CHECK / CLEAR [12/2013 - ]
Body Electrical > Power Source Control > Clear DTCs
Result
Result Proceed to Smart Key System (for Start Function) DTCs are not output A Smart Key System (for Start Function) DTCs are output B
Result: 2
B
GO TO SMART KEY SYSTEM (for Start Function). Refer to HOW TO PROCEED WITH TROUBLESHOOTING [12/2013 - ]
Result: 1
A
See step 3
- Clear the DTCs.
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Main Body > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note ACC SW Ignition switch ACC signal ON or OFF ON: Ignition switch ACC
OFF: Ignition switch off"ON" is also displayed for this item when the ignition switch is ON. Body Electrical > Main Body > Data List
Tester Display ACC SW OK
Normal conditions listed above are displayed.
Result
Proceed to OK NG
Result: 1
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [12/2013 - ]
Result: 2
NG
See step 4
- CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - BATTERY)
- Disconnect the 4K instrument panel junction block assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 4K-1 - Body ground Always 11 to 14 V Result
Proceed to OK NG
Result: 3
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 5
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
*a Component without harness connected
(Instrument Panel Junction Block Assembly)- - - Remove the instrument panel junction block assembly.
Refer to REMOVAL [12/2013 - ]
- Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Refer to REMOVAL [12/2013 - ]
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 4K-1 - MB-30 (ACC) Battery not connected to 4A-28 and 4A-27 10 kΩ or higher 4K-1 - MB-30 (ACC) Battery positive (+) → 4A-28
Battery negative (-) → 4A-27Below 1 Ω Result
Proceed to OK NG
Result: 1
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [12/2013 - ]
Result: 2
NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [12/2013 - ]
- Remove the instrument panel junction block assembly.
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Main Body > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note ACC SW Ignition switch ACC signal ON or OFF ON: Ignition switch ACC
OFF: Ignition switch off"ON" is also displayed for this item when the ignition switch is ON. Body Electrical > Main Body > Data List
Tester Display ACC SW OK
Normal conditions listed above are displayed.
Result
Proceed to OK NG
Result: 1
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [12/2013 - ]
Result: 2
NG
See step 7
- CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - ACC RELAY POWER SOURCE AND BODY GROUND)
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 4A-28 - Body ground Ignition switch ACC 11 to 14 V - Disconnect the 4A instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 4A-27 - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result: 3
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 8
- Measure the voltage according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (BATTERY POWER SOURCE)
- Disconnect the 4K instrument panel junction block assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 4K-1 - Body ground Always 11 to 14 V Result
Proceed to OK NG
Result: 3
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 9
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
*a Component without harness connected
(Instrument Panel Junction Block Assembly)- - - Remove the instrument panel junction block assembly.
Refer to REMOVAL [12/2013 - ]
- Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Refer to REMOVAL [12/2013 - ]
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 4K-1 - MB-30 (ACC) Battery not connected to 4A-28 and 4A-27 10 kΩ or higher 4K-1 - MB-30 (ACC) Battery positive (+) → 4A-28
Battery negative (-) → 4A-27Below 1 Ω Result
Proceed to OK NG
Result: 1
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [12/2013 - ]
Result: 2
NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [12/2013 - ]
- Remove the instrument panel junction block assembly.