SRS Warning Light does not Come ON [08/2013 - 12/2013]: Procedure
- CHECK AUXILIARY BATTERY VOLTAGE
- Measure the voltage of the auxiliary battery.
Standard Voltage
11 to 14 V
NG → See step 6
OK: Go to next step
- Measure the voltage of the auxiliary battery.
- CHECK CONNECTOR
- Turn the power switch off.
- Disconnect the cable from the negative (-) auxiliary battery terminal.WARNING:
Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.
- Check that the connector is properly connected to the combination meter assembly.
OK
The connector is properly connected.
HINT:
If the connector is not connected securely, reconnect the connector and proceed to the next inspection.
- Disconnect the connector from the combination meter assembly.
- Check that the terminal of the connector is not damaged.
OK
The terminal is not deformed or damaged.
NG → REPAIR OR REPLACE CONNECTOR
OK: Go to next step
- CHECK WIRE HARNESS (COMBINATION METER ASSEMBLY - BODY GROUND)
- Connect the cable to the negative (-) auxiliary battery terminal.
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition I18-13 (IG+) - Body ground Power switch on (IG) 11 to 14 V I18-1 (B) - Body ground Power switch off 11 to 14 V - Turn the power switch off.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition I18-7 (ES) - Body ground Always Below 1 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Combination Meter Assembly)
NG → REPAIR OR REPLACE WIRE HARNESS
OK: Go to next step
- Connect the cable to the negative (-) auxiliary battery terminal.
- CHECK SRS WARNING LIGHT
- Disconnect the cable from the negative (-) auxiliary battery terminal.WARNING:
Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.
- Connect the connector to the combination meter assembly.
- Disconnect the connector from the airbag sensor assembly.
- Connect the cable to the negative (-) auxiliary battery terminal.
- Turn the power switch on (IG).
- Check the SRS warning light condition.
OK
After the primary check period, the SRS warning light goes off for approximately 10 seconds and turns back on.
HINT:
The primary check period is approximately 6 seconds after the power switch is turned on (IG).
NG → See step 7
OK → See step 5
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- REPLACE AIRBAG SENSOR ASSEMBLY. Refer to REMOVAL [08/2013 - ]
- INSPECT CHARGING SYSTEM AND AUXILIARY BATTERY. Refer to ON-VEHICLE INSPECTION [08/2013 - ]