Inspection [12/2012 - ]: Procedure
- INSPECT LIGHT CONTROL RHEOSTAT
*1 Knob *a Component without harness connected
(Light Control Rheostat)- Inspect the light control rheostat.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 9 (T) - 6 (E) Always 10 +/-2 kΩ 7 (TR) - 6 (E) Knob turned fully upward 10 +/-2 kΩ 7 (TR) - 6 (E) Knob turned fully downward Below 50 Ω 7 (TR) - 6 (E) Knob turned from fully upward to fully downward 10 +/-2 kΩ → Below 50 Ω If the result is not as specified, replace the light control rheostat.
- Measure the resistance according to the value(s) in the table below.
*1 Knob *a Component without harness connected
(Light Control Rheostat)Inspect the TAIL cancel switch.
HINT:
The TAIL cancel switch is built into the light control rheostat.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 9 (T) - 8 (TC) Knob turned fully upward
(TAIL cancel condition)10 kΩ or higher 9 (T) - 8 (TC) Knob not turned fully upward Below 1 Ω If the result is not as specified, replace the light control rheostat.
- Measure the resistance according to the value(s) in the table below.
- Inspect the light control rheostat.