DTC B1244: Light Sensor Circuit Malfunction [12/2012 - ]: Procedure
- CLEAR DTC
- Clear the DTCs.
Refer to DTC CHECK / CLEAR [12/2012 - ] .
Body Electrical > Main Body > Clear DTCs
Result:
NEXT
See step 2
- Clear the DTCs.
- CHECK FOR DTC
- Check the DTCs.
Refer to DTC CHECK / CLEAR [12/2012 - ] .
Body Electrical > Main Body > Trouble Codes
Results Proceed to DTC B1244 output does not occur DTC B1244 output occur
Result:
DTC B1244 output does not occur
USE SIMULATION METHOD TO CHECK:
Refer to HOW TO PROCEED WITH TROUBLESHOOTING [12/2012 - 11/2013] .
Refer to HOW TO PROCEED WITH TROUBLESHOOTING [11/2013 - 10/2015] .
Refer to HOW TO PROCEED WITH TROUBLESHOOTING [10/2015 - 08/2016] .
Refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2016 - 08/2017] .
Refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2017 - ] .
Result:
DTC B1244 output occur
See step 3
- Check the DTCs.
- READ VALUE USING TECHSTREAM (AUTOMATIC LIGHT CONTROL SENSOR)
- Using the Techstream, read the Data List.
Refer to DATA LIST / ACTIVE TEST [12/2012 - ] .
Body Electrical > Main Body > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Illumination Rate Info Illumination rate information 0 ms. to 2162.65 ms. Value output according to ambient light levels - Body Electrical > Main Body > Data List
Tester Display Illumination Rate Info OK
The display is as specified in the normal condition column.
Result:
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [12/2012 - ] .
Result:
NG
See step 4
- Using the Techstream, read the Data List.
- CHECK HARNESS AND CONNECTOR (MAIN BODY ECU [MULTIPLEX NETWORK BODY ECU] - AUTOMATIC LIGHT CONTROL SENSOR)
- Disconnect the G78 main body ECU (multiplex network body ECU) connector.
- Disconnect the G2 automatic light control sensor connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G78-22 (CLTE) - G2-3 (CLTE) Always Below 1 Ω G78-21 (CLTS) - G2-5 (CLTS) Always Below 1 Ω G78-20 (CLTB) - G2-6 (CLTB) Always Below 1 Ω G78-22 (CLTE) - Body ground Always 10 kΩ or higher G78-21 (CLTS) - Body ground Always 10 kΩ or higher G78-20 (CLTB) - Body ground Always 10 kΩ or higher
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 5
- CHECK MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)
- Remove the instrument panel junction block assembly and main body ECU (multiplex network body ECU) as a unit with the connectors still connected.
Refer to REMOVAL [12/2012 - ] .
*a Component with harness connected
(Main Body ECU [Multiplex Network Body ECU]) - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition G78-20 (CLTB) - G78-22 (CLTE) Ignition switch off Below 1 V Ignition switch ON 11 to 14 V
Result:
NG
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [12/2012 - ] .
Result:
OK
See step 6
- Remove the instrument panel junction block assembly and main body ECU (multiplex network body ECU) as a unit with the connectors still connected.
- CHECK AUTOMATIC LIGHT CONTROL SENSOR
- Check the automatic light control sensor.
Refer to REMOVAL [12/2012 - ] .
Result:
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [12/2012 - ] .
Result:
NG
REPLACE AUTOMATIC LIGHT CONTROL SENSOR. Refer to REMOVAL [12/2012 - ] .
- Check the automatic light control sensor.