LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2013 >> RAV4 EV >> Repair and Diagnosis >> External Pages >> Different car >> Section 33 (Battery / Charging System (Inspection) (Electric)) >> Charging System >> On-Vehicle Inspection [09/2013 - ] >> On-Vehicle Inspection [09/2013 - ]

On-Vehicle Inspection [09/2013 - ]

WARNING: This page is about a different car, the 2014 Toyota RAV4. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK AUXILIARY BATTERY 
    1. Check that the auxiliary battery cables are connected to the correct terminals.

      HINT: 

      If they are not, connect them properly.

    2. Check the auxiliary battery for damage and deformation. If severe damage, deformation or leakage is found, replace the auxiliary battery.
  2. CHECK AUXILIARY BATTERY VOLTAGE 
    1. Turn the power switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.
    2. Measure the auxiliary battery voltage according to the value(s) in the table below.

      Result

      Tester Connection Condition Specified Condition Result
      Positive (+) terminal - Negative (-) terminal 20°C (68°F), Power switch off 12.5 V or higher Auxiliary battery is OK
      11.0 to 12.5 V Recharge auxiliary battery
      Below 11.0 V Replace auxiliary battery
  3. RECHARGE AUXILIARY BATTERY 
    1. Recharge the auxiliary battery.

      HINT: 

      • Recharge the auxiliary battery according to the charger's instructions.
      • Apply the appropriate charging current according to the type of auxiliary battery as shown in the table below.
      Auxiliary Battery Type Charging Current
      55D23L 4 to 5 A
    2. Turn the power switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.
    3. Measure the auxiliary battery voltage according to the value(s) in the table below.

      Result

      Tester Connection Condition Specified Condition Result
      Positive (+) terminal - Negative (-) terminal 20°C (68°F), Power switch off 12.5 V or higher Auxiliary battery is OK
      11.0 to 12.5 V Recharge auxiliary battery
      Below 11.0 V Replace auxiliary battery
  4. CHECK AUXILIARY BATTERY TERMINAL, FUSIBLE LINK AND FUSE 
    1. Check that the auxiliary battery terminals are not loose or corroded.

      HINT: 

      If the terminals are corroded, clean them.

    2. Measure the resistance of each fusible link and fuse for the auxiliary battery charging system.

      Standard resistance

      Below 1 Ω

      HINT: 

      If any of the results is not as specified, replace the fusible link or fuse as necessary.

  5. CHECK DC/DC CONVERTER FUNCTION 
    1. Connect an AC/DC 400 A probe to the positive auxiliary battery cable.
      Fig 1: Identifying DC/DC Converter Function
      GTY321254Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      TEXT IN ILLUSTRATION

      *a Probe Direction
      *b Current Flowing into Auxiliary Battery
    2. Turn the power switch on (READY) and leave the vehicle as it is until the electric current flowing into the auxiliary battery becomes 10 A or less.
    3. Set the headlight position switch and blower motor switch to the HI position, and then turn the rear window defogger on.
    4. Measure the current and voltage according to the value(s) in the table below.
      Fig 2: Identifying Probe Direction And Current Flowing From Auxiliary Battery
      GTY315350Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      TEXT IN ILLUSTRATION

      *a Probe Direction
      *b Current Flowing into Auxiliary Battery

      Result

      Item Tester Connection Condition Specified Condition
      Current flowing from auxiliary battery Auxiliary battery positive cable Power switch on (READY)
      (The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.)
      0 A or less
      (no current from auxiliary battery)
      Auxiliary battery voltage Positive (+) terminal - Negative (-) terminal 13 to 15 V

      HINT: 