Problem Symptoms Table
HINT:
Use the table below to help determine the cause of problem symptoms. If multiple suspected areas are listed, the potential causes of the symptoms are listed in order of probability in the "Suspected Area" column of the table. Check each symptom by checking the suspected areas in the order they are listed. Replace parts as necessary.
CLOCK
| Symptom | Suspected Area | See |
|---|---|---|
| Clock does not operate at all. | Fuse (ECU-B, GAUGE) | - |
| Wire Harness or Connector | - | |
| Combination Meter Assembly (No. 3 Meter Circuit Plate) | Refer to DISASSEMBLY | |
| Clock display illumination malfunction | PANEL Fuse | - |
| Wire Harness or Connector | - | |
| Combination Meter Assembly (No. 3 Meter Circuit Plate) | Refer to DISASSEMBLY | |
| Clock loses or gains time. | Combination Meter Assembly (No. 3 Meter Circuit Plate) | Refer to DISASSEMBLY |
| Clock cannot be adjusted. | Trip Switch | Refer to INSPECTION |
| Wire Harness or Connector | - | |
| Combination Meter Assembly (No. 3 Meter Circuit Plate) | Refer to DISASSEMBLY |