Pattern Select Switch: Inspection: Inspection
- INSPECT PATTERN SELECT SWITCH ASSEMBLY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 6 (CS) - 3 (E1) Pattern select switch assembly not pressed 10 kΩ or higher Pattern select switch assembly pressed Below 1 Ω - Apply auxiliary battery voltage from the wire harness back side between the terminals of the switch, and check the lighting condition of the pattern select switch assembly.
OK
Measurement Condition Condition Specified Condition Auxiliary battery positive (+) → 5 (ILL+)
Auxiliary battery negative (-) → 4 (ILL-)Always Pattern select switch assembly illuminates TEXT IN ILLUSTRATION*a Component without harness connected
(Pattern Select Switch Assembly)If the result is not as specified, replace the pattern select switch assembly.
- Measure the resistance according to the value(s) in the table below.