Entire Combination Meter does not Operate: Procedure
- INSPECT COMBINATION METER
- Disconnect the E55 connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition E55-30 (ET) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition E55-32 (B) - Body ground Always 11 to 14 V E55-33 (IG+) - Body ground Ignition switch ON 11 to 14 V
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 2
- REPLACE COMBINATION METER. Refer to REMOVAL - Step 4