DTC B1507: Open in Turn Signal Circuit; DTC B1508: Short in Turn Signal / Hazard Flasher Circuit: Procedure
- INSPECT LIGHTS
- Inspect each turn signal light illumination.RESULT
Result Proceed to One side of the turn signal lights does not illuminate. A Front turn signal lights do not illuminate. B Rear turn signal lights do not illuminate. C
B → See step 3
C → See step 4
A: Go to next step
- Inspect each turn signal light illumination.
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Disconnect the D101 combination meter assembly connector.
- Disconnect the 3B instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
FOR LHTester Connection Condition Specified Condition D101-13 (LL) - 3B-24 Always Below 1 Ω D101-13 (LL) - Body ground Always 10 kΩ or higher FOR RHTester Connection Condition Specified Condition D101-7 (LR) - 3B-25 Always Below 1 Ω D101-7 (LR) - Body ground Always 10 kΩ or higher RESULTResult Proceed to NG A OK B
B → See step 5
A → REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (FRONT TURN SIGNAL LIGHT - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Disconnect the A42*1 or A43*2 front turn signal light connector.
- *1: for RH
- *2: for LH
- Disconnect the 3C instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
FOR LHTester Connection Condition Specified Condition A43-1 (B) - 3C-28 Always Below 1 Ω A43-2 (E) - Body ground Always Below 1 Ω A43-1 (B) - Body ground Always 10 kΩ or higher FOR RHTester Connection Condition Specified Condition A42-1 (B) - 3C-38 Always Below 1 Ω A42-2 (E) - Body ground Always Below 1 Ω A42-1 (B) - Body ground Always 10 kΩ or higher RESULTResult Proceed to NG A OK B
B → See step 5
A → REPAIR OR REPLACE HARNESS OR CONNECTOR
- Disconnect the A42*1 or A43*2 front turn signal light connector.
- CHECK HARNESS AND CONNECTOR (REAR TURN SIGNAL LIGHT - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Disconnect the J65*1 or J64*2 rear turn signal light connector.
- *1: for RH
- *2: for LH
- Disconnect the 3D instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
FOR LHTester Connection Condition Specified Condition J64-2 (B) - 3D-18 Always Below 1 Ω J64-6 (E) -Body ground Always Below 1 Ω J64-2 (B) -Body ground Always 10 kΩ or higher FOR RHTester Connection Condition Specified Condition J65-2 (B) - 3D-5 Always Below 1 Ω J65-6 (E) -Body ground Always Below 1 Ω J65-2 (B) -Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- Disconnect the J65*1 or J64*2 rear turn signal light connector.
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
- Remove the instrument panel junction block assembly. Refer to REMOVAL .
- Remove the main body ECU (multiplex network body ECU). Refer to REMOVAL - Step 7 .
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3B-25 - 3C-38 Always Below 1 Ω 3B-25 - 3D-5 Always Below 1 Ω 3B-24 - 3C-28 Always Below 1 Ω 3B-24 - 3D-18 Always Below 1 Ω
NG → See step 7
OK → See step 6
- REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL
- REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL