Operating Light Control Rheostat does not Change Light Brightness: Procedure
- READ VALUE USING TECHSTREAM (RHEOSTAT)
- Connect the Techstream to the DLC3.
- Turn the ignition switch ON and turn the tester ON.
- Select the item below in the Data List, and read the value displayed on the Techstream.
Body Electrical / Combination Meter / Data List:
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Rheostat value (A/D) Rheostat value
Min.: 0
Max.: 255Light control rheostat switch is Dark (0)→Bright (255) - OK
Light brightness can be changed within the specified range by actual operation.
NG → See step 2
OK → REPLACE COMBINATION METER ASSEMBLY
- INSPECT FUSE (GAUGE)
- Remove the GAUGE fuse from the main body ECU.
- Measure the resistance.
OK
Below 1 Ω
- Reinstall the GAUGE fuse.
NG → REPLACE FUSE
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (FUSE (GAUGE) - LIGHT CONTROL RHEOSTAT)
- Disconnect the D29 light control rheostat connector.
- Measure the voltage.
Standard voltage
Tester Connection Condition Specified Condition D29-10 - Body ground Ignition switch ON 11 to 14V - Reconnect the light control rheostat connector.
OK → See step 5
NG: Go to next step
- CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - LIGHT CONTROL RHEOSTAT)
- Disconnect the D29 light control rheostat connector.
- Disconnect the 4P main body ECU connector.
- Measure the resistance.
Standard resistance
Tester Condition Specified Condition D29-10 (IG)- 4P-1 Always Below 1 Ω - Reconnect the light control rheostat connector.
- Reconnect the main body ECU connector.
NG → REPLACE MAIN BODY ECU
OK: Go to next step
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat but without disconnecting the connector.
- Turn the ignition switch ON.
- Using an oscilloscope, check the signal waveform of the light control rheostat.
Item Contents Terminal connection D29-2 (RV) - Body ground Tool setting 5V / DIV, 50ms / DIV Vehicle condition Ignition switch ON OK
Waveform is as shown in the illustration.
HINT:
Duty ratio changes as the illumination dims. (A becomes longer)
- Reinstall the light control rheostat.
NG → See step 8
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT)
- Disconnect the D1 combination meter assembly connector.
- Disconnect the D29 light control rheostat connector.
- Measure the resistance.
Standard resistance
Tester Connection Specified Condition D1-7 (ILL-) - D29-2 (RV) Below 1 Ω - Reconnect the combination meter assembly.
- Reconnect the light control rheostat connector.
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 7
- REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL
- REPLACE LIGHT CONTROL RHEOSTAT. Refer to REMOVAL