Entire Combination Meter does not Operate: Procedure
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
- Disconnect the D18 combination meter assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition D18-21 (IG+) - Body ground Ignition switch ON 11 to 14 V D18-1 (B) - Body ground Always 11 to 14 V D18-2 (B2) - Body ground Always 11 to 14 V - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition D18-20 (ES) - Body ground Always Below 1 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Combination Meter Assembly)
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 2
- REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL