Entire Combination Meter does not Operate: Procedure
- INSPECT FUSE (GAUGE2, ECU-B, IG2)
- Remove the GAUGE2 fuse from the instrument panel junction block.
- Remove the ECU-B fuse from the engine room No. 2 relay block.
- Remove the IG2 fuse from the engine room No. 1 relay block.
- Measure the resistance of the fuses.
Standard resistance
Below 1 Ω
NG → REPLACE FUSE
OK: Go to next step
- INSPECT IG2 RELAY
- Remove the IG2 relay from the No. 1 relay block.
- Measure the resistance of the relay.
Standard resistance
Tester Connection Specified Condition 3 - 5 10 kΩ or higher 3 - 5 Below 1 Ω
(when battery voltage is applied to terminals 1 and 2)
NG → REPLACE IG2 RELAY
OK: Go to next step
- CHECK WIRE HARNESS (COMBINATION METER - BATTERY AND BODY GROUND)
- Disconnect the E19 meter connector.
- Measure the voltage of the wire harness side connector.
Standard voltage
Tester Connection Condition Specified Condition E19-22 (B) - Body ground Always 11 to 14 V E19-21 (IG+) - Body ground Ignition switch ON 11 to 14 V - Measure the resistance of the wire harness side connector.
Standard resistance
Tester Connection Specified Condition E19-33 (ET) - Body ground Below 1 Ω
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → REPLACE COMBINATION METER ASSEMBLY