DTC P3233-750: Open or Short to B+ in Blocking of HV Gate Connection: Procedure
- CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER) WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair information because this may cause a malfunction.
- Disconnect connector A59 from the inverter with converter assembly.
- Disconnect connector A22 from the power management control ECU.
- Connect the cable to the negative (-) auxiliary battery terminal.
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard Voltage
Tester Connection Switch Condition Specified Condition A22-31 (HSDN) - Body ground Power switch on (IG) Below 1 V TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Inverter with Converter Assembly)*b Rear view of wire harness connector
(to Power Management Control ECU)NOTE:Turning the power switch on (IG) with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Turn the power switch off.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition A22-31 (HSDN) - A59-31 (HSDN) Power switch off Below 1 Ω - Connect the inverter with converter assembly connector.
- Connect the power management control ECU connector.
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- Check that the service plug grip is not installed.
- CHECK INVERTER WITH CONVERTER ASSEMBLY WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair information because this may cause a malfunction.
- Disconnect connector A59 from the inverter with converter assembly.
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard Resistance
Tester Connection Switch Condition Specified Condition A59-31 (HSDN) - A59-10 (+B) Power switch off 80 Ω or higher A59-31 (HSDN) - A59-9 (+B2) Power switch off 80 Ω or higher A59-31 (HSDN) - A59-28 (GND1) Power switch off 2.65 to 3.55 kΩ TEXT IN ILLUSTRATION*a Component without harness connected
(Inverter with Converter Assembly) - Connect the inverter with converter assembly connector.
NG → See step 4
OK → See step 3
- Check that the service plug grip is not installed.
- REPLACE POWER MANAGEMENT CONTROL ECU. Refer to COMPONENTS
- REPLACE INVERTER WITH CONVERTER ASSEMBLY. Refer to COMPONENTS