DTC P0AA4-232: Hybrid Battery Negative Contactor Circuit Stuck Closed: Procedure
- CHECK DTC OUTPUT (HYBRID CONTROL)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Check if DTCs are output.
Result
Result Proceed to P0AA4-232 only is output. A DTCs shown in Table 1 are output simultaneously. B DTCs shown in Table 2 are output simultaneously. C TABLE 1DTC No. Relevant Diagnosis P0A1A-151, 155, 156, 200, 658, 659, 791, 792, 793 Generator Control Module P0A1B-163, 164, 168, 193, 511, 512, 661, 786, 794, 795, 796 Drive Motor "A" Control Module P0A1D-148 Hybrid Powertrain Control Module P0A3F-243 Drive Motor "A" Position Sensor Circuit P0A40-500 Drive Motor "A" Position Sensor Circuit Range/Performance P0A41-245 Drive Motor "A" Position Sensor Circuit Low P0A4B-253 Generator Position Sensor Circuit P0A4C-513 Generator Position Sensor Circuit Range/Performance P0A4D-255 Generator Position Sensor Circuit Low P0A78-266, 267, 586 Drive Motor "A" Inverter Performance P0A94-442 DC / DC Converter Performance P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High P0AE6-225 Hybrid Battery Precharge Contactor Control Circuit Low P0AE7-224 Hybrid Battery Precharge Contactor Control Circuit High P0AFC-129 Hybrid Battery Pack Sensor Module P0C76-523 Hybrid Battery System Discharge Time Too Long P2511-149 ECM/PCM Power Relay Sensor Circuit Intermittent P3004-132 Power Cable Malfunction P324E-788 MG-ECU Power Relay Intermittent Circuit U0110 (all INF codes)*1 Lost Communication with Drive Motor Control Module "A" TABLE 2DTC No. Relevant Diagnosis P0AFC-123 Hybrid Battery Pack Sensor Module P0B3D-123 Hybrid Battery Voltage Sensor "A" Circuit Low P0B42-123 Hybrid Battery Voltage Sensor "B" Circuit Low P0B47-123 Hybrid Battery Voltage Sensor "C" Circuit Low P0B4C-123 Hybrid Battery Voltage Sensor "D" Circuit Low P0B51-123 Hybrid Battery Voltage Sensor "E" Circuit Low P0B56-123 Hybrid Battery Voltage Sensor "F" Circuit Low P0B5B-123 Hybrid Battery Voltage Sensor "G" Circuit Low P0B60-123 Hybrid Battery Voltage Sensor "H" Circuit Low P0B65-123 Hybrid Battery Voltage Sensor "I" Circuit Low P0B6A-123 Hybrid Battery Voltage Sensor "J" Circuit Low P0B6F-123 Hybrid Battery Voltage Sensor "K" Circuit Low P0B74-123 Hybrid Battery Voltage Sensor "L" Circuit Low P0B79-123 Hybrid Battery Voltage Sensor "M" Circuit Low P0B7E-123 Hybrid Battery Voltage Sensor "N" Circuit Low P0B83-123 Hybrid Battery Voltage Sensor "O" Circuit Low P308A-123 Hybrid Battery Voltage Sensor All Circuits Low HINT:
- *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
- P0AA4-232 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.
- Turn the power switch off.
B → See step 6
C → See step 7
A: Go to next step
- CHECK FREEZE FRAME DATA (HYBRID CONTROL)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Read the freeze frame data of DTC P0AA4-232.
Result
Result Proceed to HV battery current (IB) is 3 A or more. A HV battery current (IB) is less than 3 A. B - Turn the power switch off.
B → See step 5
A: Go to next step
- CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair information because this may cause a malfunction.
- Remove the upper hybrid battery cover sub-assembly. Refer to REMOVAL - Step 19 .
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard Resistance
Tester Connection Switch Condition Specified Condition T3-1 (CEI) - k2-1 (-) Power switch off 10 kΩ or higher TEXT IN ILLUSTRATION*1 Hybrid Battery Junction Block Assembly HINT:
- If a system main relay is stuck closed, inspect the hybrid battery junction block assembly without removing it from the vehicle, in order to keep the relay closed.
- If the result of reading the freeze frame data is A, the hybrid battery junction block assembly must be replaced. Measuring resistance can determine that this is either a present or past malfunction.
- Install the upper hybrid battery cover sub-assembly.
NG → See step 4
OK → See step 4
- Check that the service plug grip is not installed.
- REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY. Refer to COMPONENTS
- REPLACE INVERTER WITH CONVERTER ASSEMBLY. Refer to COMPONENTS
- GO TO DTC CHART (HYBRID CONTROL SYSTEM). Refer to DIAGNOSTIC TROUBLE CODE CHART
- GO TO DTC CHART (HYBRID BATTERY SYSTEM). Refer to DIAGNOSTIC TROUBLE CODE CHART