LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2012 >> Prius V >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Testing and Diagnosis >> Hybrid Control System [Diagnostic Codes (P0A78-121 - P0AA1-233)] >> Hybrid Control System >> DTC P0A94-548: DC / DC Converter Performance >> Procedure

DTC P0A94-548: DC / DC Converter Performance: Procedure

  1. CHECK DTC OUTPUT (HYBRID CONTROL) 
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (IG).
    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
    4. Check if DTCs are output.

      Result

      Result Proceed to
      DTC P0A94-548 only is output. A
      Any of the following DTCs are also output. B
      DTC No. Relevant Diagnosis
      P0A1A (all INF codes)*1 Generator Control Module
      P0A1B (all INF codes)*1 Drive Motor "A" Control Module
      P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
      P0A3F-243 Drive Motor "A" Position Sensor Circuit
      P0A40-500 Drive Motor "A" Position Sensor Circuit Range / Performance
      P0A41-245 Drive Motor "A" Position Sensor Circuit Low
      P0A4B-253 Generator Position Sensor Circuit
      P0A4C-513 Generator Position Sensor Circuit Range / Performance
      P0A4D-255 Generator Position Sensor Circuit Low
      P0A60 (all INF codes)*1 Drive Motor "A" Phase V Current
      P0A63 (all INF codes)*1 Drive Motor "A" Phase W Current
      P0A72 (all INF codes)*1 Generator Phase V Current
      P0A75 (all INF codes)*1 Generator Phase W Current
      P0A78-266, 267, 287, 505, 506, 586, 806, 807, 808 Drive Motor "A" Inverter Performance
      P0A7A-325, 517, 518, 809, 810, 811 Generator Inverter Performance
      P0A94-554, 555, 556, 564, 585, 587, 589, 590 DC / DC Converter Performance
      P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low
      P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High
      P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low
      P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High
      P0C76-523 Hybrid Battery System Discharge Time Too Long
      P3004-803 High Voltage Power Resource

      HINT: 

      • *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
      • P0A94-548 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
    5. Turn the power switch off.

    B → See step   3 

    A: Go to next step 

  2. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR). Refer to  PROCEDURE - Step 4 

    NG → CONNECT SECURELY 

    OK → See step   4 

  3. GO TO DTC CHART (HYBRID CONTROL SYSTEM). Refer to  DIAGNOSTIC TROUBLE CODE CHART 
  4. REPLACE INVERTER WITH CONVERTER ASSEMBLY. Refer to  COMPONENTS