DTC P082B-575: Gear Lever X Position Circuit Low; DTC P082C-576: Gear Lever X Position Circuit High; DTC P082E-571: Gear Lever Y Position Circuit Low; DTC P082F-572: Gear Lever Y Position Circuit High; DTC P181A-596: Gear Lever X Position Circuit "A" / "B" Correlation; DTC P181B-595: Gear Lever Y Position Circuit "A" / "B" Correlation; DTC P182B-577: Gear Lever X Position "B" Circuit Low; DTC P182C-578: Gear Lever X Position "B" Circuit High; DTC P182E-573: Gear Lever Y Position "B" Circuit Low; DTC P182F-574: Gear Lever Y Position "B" Circuit High: Procedure
- READ VALUE USING TECHSTREAM (SHIFT SENSOR MAIN, SHIFT SENSOR SUB)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Data List / Shift Sensor Main, Shift Sensor Sub.
- Read the Data List.
Result
Tester Display Condition Specified Condition Shift Sensor Main R position 0.3 to 1.8 V Home or N position 2.0 to 3.0 V D or B position 3.2 to 4.8 V Shift Sensor Sub R position 0.3 to 1.8 V Home or N position 2.0 to 3.0 V D or B position 3.2 to 4.8 V - Turn the power switch off.
NG → See step 6
OK: Go to next step
- READ VALUE USING TECHSTREAM (SHIFT SENSOR SELECT MAIN, SHIFT SENSOR SELECT SUB)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Data List / Shift Sensor Select Main, Shift Sensor Select Sub.
- Read the Data List.
Result
Tester Display Condition Specified Condition Shift Sensor Select Main R, N or D Position 2.9 to 4.3 V Home or B Position 1.0 to 1.6 V Shift Sensor Select Sub R, N or D Position 2.9 to 4.3 V Home or B Position 1.0 to 1.6 V - Turn the power switch off.
NG → See step 12
OK: Go to next step
- REPLACE SHIFT LOCK CONTROL UNIT ASSEMBLY
Refer to COMPONENTS
NEXT: Go to next step
- CLEAR DTC
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Read and record the DTCs and freeze frame data.
- Clear DTCs and freeze frame data.
- Turn the power switch off.
NEXT: Go to next step
- CHECK DTC OUTPUT (HYBRID CONTROL)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Perform a road test.
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Check if DTCs are output.
Result
Result Proceed to No DTCs are output. A P082B-575, P082C-576, P082E-571, P082F-572, P181A-596, P181B-595, P182B-577, P182C-578, P182E-573 or P182F-574 is output again. B - Turn the power switch off.
B → See step 20
A → COMPLETED
- CHECK HARNESS AND CONNECTOR (+B SHORT)
- Remove the IGCT NO. 2 fuse and AM2 fuse from the engine room relay block and junction block assembly.Fig 1: Identifying IGCT No. 2 Fuse And AM2 Fuse & Engine Room Relay Block And Junction Block Assembly
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
TEXT IN ILLUSTRATION*1 Engine Room Relay Block and Junction Block Assembly *2 AM2 Fuse *3 IGCT NO. 2 Fuse - Disconnect connector L127 from the shift sensor.
- Measure the resistance according to the value(s) in the table below.TEXT IN ILLUSTRATION
*a Component with harness connected
(Power Management Control ECU)- - Standard Resistance
Tester Connection Switch Condition Specified Condition L5-26 (VCX1) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-26 (VCX1) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-26 (VCX1) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-26 (VCX1) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-26 (VCX1) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-26 (VCX1) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-26 (VCX1) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-26 (VCX1) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-26 (VCX1) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-26 (VCX1) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-26 (VCX1) - A21-16 (GI) Power switch off 10 kΩ or higher L5-26 (VCX1) - A21-4 (FCTL) Power switch off 10 kΩ or higher Standard Resistance
Tester Connection Switch Condition Specified Condition L5-25 (VSX1) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-25 (VSX1) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-25 (VSX1) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-25 (VSX1) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-25 (VSX1) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-25 (VSX1) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-25 (VSX1) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-25 (VSX1) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-25 (VSX1) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-25 (VSX1) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-25 (VSX1) - A21-16 (GI) Power switch off 10 kΩ or higher L5-25 (VSX1) - A21-4 (FCTL) Power switch off 10 kΩ or higher Standard Resistance
Tester Connection Switch Condition Specified Condition L5-24 (E2X1) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-24 (E2X1) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-24 (E2X1) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-24 (E2X1) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-24 (E2X1) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-24 (E2X1) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-24 (E2X1) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-24 (E2X1) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-24 (E2X1) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-24 (E2X1) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-24 (E2X1) - A21-16 (GI) Power switch off 10 kΩ or higher L5-24 (E2X1) - A21-4 (FCTL) Power switch off 10 kΩ or higher Standard Resistance
Tester Connection Switch Condition Specified Condition L5-21 (VCX2) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-21 (VCX2) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-21 (VCX2) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-21 (VCX2) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-21 (VCX2) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-21 (VCX2) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-21 (VCX2) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-21 (VCX2) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-21 (VCX2) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-21 (VCX2) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-21 (VCX2) - A21-16 (GI) Power switch off 10 kΩ or higher L5-21 (VCX2) - A21-4 (FCTL) Power switch off 10 kΩ or higher Standard Resistance
Tester Connection Switch Condition Specified Condition L5-22 (VSX2) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-22 (VSX2) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-22 (VSX2) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-22 (VSX2) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-22 (VSX2) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-22 (VSX2) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-22 (VSX2) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-22 (VSX2) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-22 (VSX2) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-22 (VSX2) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-22 (VSX2) - A21-16 (GI) Power switch off 10 kΩ or higher L5-22 (VSX2) - A21-4 (FCTL) Power switch off 10 kΩ or higher Standard Resistance
Tester Connection Switch Condition Specified Condition L5-23 (E2X2) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-23 (E2X2) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-23 (E2X2) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-23 (E2X2) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-23 (E2X2) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-23 (E2X2) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-23 (E2X2) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-23 (E2X2) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-23 (E2X2) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-23 (E2X2) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-23 (E2X2) - A21-16 (GI) Power switch off 10 kΩ or higher L5-23 (E2X2) - A21-4 (FCTL) Power switch off 10 kΩ or higher - Connect the shift sensor connector.
- Install the IGCT NO. 2 fuse and AM2 fuse.
NG → See step 18
OK: Go to next step
- Remove the IGCT NO. 2 fuse and AM2 fuse from the engine room relay block and junction block assembly.
- CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - SHIFT SENSOR)
- Disconnect connector L5 from the power management control ECU.
- Disconnect connector L127 from the shift sensor.
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard Resistance (Check for Open)
Tester Connection Switch Condition Specified Condition L5-26 (VCX1) - L127-3 (VCX1) Power switch off Below 1 Ω L5-25 (VSX1) - L127-1 (VSX1) Power switch off Below 1 Ω L5-24 (E2X1) - L127-2 (E2X1) Power switch off Below 1 Ω L5-21 (VCX2) - L127-6 (VCX2) Power switch off Below 1 Ω L5-22 (VSX2) - L127-4 (VSX2) Power switch off Below 1 Ω L5-23 (E2X2) - L127-5 (E2X2) Power switch off Below 1 Ω Standard Resistance (Check for Short)
Tester Connection Switch Condition Specified Condition L5-26 (VCX1) or L127-3 (VCX1) - Body ground and other terminals Power switch off 10 kΩ or higher L5-25 (VSX1) or L127-1 (VSX1) - Body ground and other terminals Power switch off 10 kΩ or higher L5-24 (E2X1) or L127-2 (E2X1) - Body ground and other terminals Power switch off 10 kΩ or higher L5-21 (VCX2) or L127-6 (VCX2) - Body ground and other terminals Power switch off 10 kΩ or higher L5-22 (VSX2) or L127-4 (VSX2) - Body ground and other terminals Power switch off 10 kΩ or higher L5-23 (E2X2) or L127-5 (E2X2) - Body ground and other terminals Power switch off 10 kΩ or higher TEXT IN ILLUSTRATION*a Rear view of wire harness connector
(to Power Management Control ECU)*b Front view of wire harness connector
(to Shift Sensor)HINT:
As necessary, check that there is no short to power supply wires when performing the above wire harness inspection.
- Connect the shift sensor connector.
- Connect the power management control ECU connector.
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK POWER MANAGEMENT CONTROL ECU (VCX1, VCX2 VOLTAGE)
- Disconnect connector L127 from the shift sensor.
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard Voltage
Tester Connection Switch Condition Specified Condition L127-3 (VCX1) - L127-2 (E2X1) Power switch on (IG) 4.5 to 5.5 V L127-6 (VCX2) - L127-5 (E2X2) Power switch on (IG) 4.5 to 5.5 V TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Shift Sensor)NOTE:Turning the power switch on (IG) with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
- Turn the power switch off.
- Connect the shift sensor connector.
NG → See step 20
OK: Go to next step
- REPLACE SHIFT LOCK CONTROL UNIT ASSEMBLY
Refer to COMPONENTS
NEXT: Go to next step
- CLEAR DTC
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Read and record the DTCs and freeze frame data.
- Clear DTCs and freeze frame data.
- Turn the power switch off.
NEXT: Go to next step
- CHECK DTC OUTPUT (HYBRID CONTROL)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Perform a road test.
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Check if DTCs are output.
Result
Result Proceed to No DTCs are output. A P082B-575, P082C-576, P082E-571, P082F-572, P181A-596, P181B-595, P182B-577, P182C-578, P182E-573 or P182F-574 is output again. B - Turn the power switch off.
B → See step 20
A → COMPLETED
- CHECK HARNESS AND CONNECTOR (+B SHORT)
- Remove the IGCT NO. 2 fuse and AM2 fuse from the engine room relay block and junction block assembly.Fig 5: Identifying IGCT No. 2 Fuse And AM2 Fuse & Engine Room Relay Block And Junction Block Assembly
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
TEXT IN ILLUSTRATION*1 Engine Room Relay Block and Junction Block Assembly *2 AM2 Fuse *3 IGCT NO. 2 Fuse - Disconnect connector L126 from the select sensor.
- Measure the resistance according to the value(s) in the table below.TEXT IN ILLUSTRATION
*a Component with harness connected
(Power Management Control ECU)- - Standard Resistance
Tester Connection Switch Condition Specified Condition L5-19 (VCX3) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-19 (VCX3) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-19 (VCX3) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-19 (VCX3) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-19 (VCX3) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-19 (VCX3) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-19 (VCX3) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-19 (VCX3) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-19 (VCX3) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-19 (VCX3) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-19 (VCX3) - A21-16 (GI) Power switch off 10 kΩ or higher L5-19 (VCX3) - A21-4 (FCTL) Power switch off 10 kΩ or higher Standard Resistance
Tester Connection Switch Condition Specified Condition L5-20 (VSX3) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-20 (VSX3) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-20 (VSX3) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-20 (VSX3) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-20 (VSX3) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-20 (VSX3) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-20 (VSX3) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-20 (VSX3) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-20 (VSX3) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-20 (VSX3) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-20 (VSX3) - A21-16 (GI) Power switch off 10 kΩ or higher L5-20 (VSX3) - A21-4 (FCTL) Power switch off 10 kΩ or higher Standard Resistance
Tester Connection Switch Condition Specified Condition L5-17 (VCX4) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-17 (VCX4) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-17 (VCX4) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-17 (VCX4) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-17 (VCX4) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-17 (VCX4) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-17 (VCX4) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-17 (VCX4) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-17 (VCX4) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-17 (VCX4) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-17 (VCX4) - A21-16 (GI) Power switch off 10 kΩ or higher L5-17 (VCX4) - A21-4 (FCTL) Power switch off 10 kΩ or higher Standard Resistance
Tester Connection Switch Condition Specified Condition L5-18 (VSX4) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-18 (VSX4) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-18 (VSX4) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-18 (VSX4) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-18 (VSX4) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-18 (VSX4) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-18 (VSX4) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-18 (VSX4) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-18 (VSX4) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-18 (VSX4) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-18 (VSX4) - A21-16 (GI) Power switch off 10 kΩ or higher L5-18 (VSX4) - A21-4 (FCTL) Power switch off 10 kΩ or higher - Connect the select sensor connector.
- Install the IGCT NO. 2 fuse and AM2 fuse.
NG → See step 19
OK: Go to next step
- Remove the IGCT NO. 2 fuse and AM2 fuse from the engine room relay block and junction block assembly.
- CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - SELECT SENSOR)
- Disconnect connector L5 from the power management control ECU.
- Disconnect connector L126 from the select sensor.
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard Resistance (Check for Open)
Tester Connection Switch Condition Specified Condition L5-19 (VCX3) - L126-5 (VCX3) Power switch off Below 1 Ω L5-20 (VSX3) - L126-4 (VSX3) Power switch off Below 1 Ω L5-17 (VCX4) - L126-2 (VCX4) Power switch off Below 1 Ω L5-18 (VSX4) - L126-1 (VSX4) Power switch off Below 1 Ω Standard Resistance (Check for Short)
Tester Connection Switch Condition Specified Condition L5-19 (VCX3) or L126-5 (VCX3) - Body ground and other terminals Power switch off 10 kΩ or higher L5-20 (VSX3) or L126-4 (VSX3) - Body ground and other terminals Power switch off 10 kΩ or higher L5-17 (VCX4) or L126-2 (VCX4) - Body ground and other terminals Power switch off 10 kΩ or higher L5-18 (VSX4) or L126-1 (VSX4) - Body ground and other terminals Power switch off 10 kΩ or higher TEXT IN ILLUSTRATION*a Rear view of wire harness connector:
(to Power Management Control ECU)*b Front view of wire harness connector:
(to Select Sensor)HINT:
As necessary, check that there is no short to power supply wires when performing the above wire harness inspection.
- Connect the select sensor connector.
- Connect the power management control ECU connector.
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK POWER MANAGEMENT CONTROL ECU (VCX3, VCX4 VOLTAGE)
- Disconnect connector L126 from the select sensor.
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard Voltage
Tester Connection Switch Condition Specified Condition L126-5 (VCX3) - Body ground Power switch on (IG) 9 to 14 V L126-2 (VCX4) - Body ground Power switch on (IG) 9 to 14 V TEXT IN ILLUSTRATION*a Front view of wire harness connector:
(to Select Sensor)NOTE:Turning the power switch on (IG) with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
- Turn the power switch off.
- Connect the select sensor connector.
NG → See step 20
OK: Go to next step
- REPLACE SHIFT LOCK CONTROL UNIT ASSEMBLY
Refer to COMPONENTS
NEXT: Go to next step
- CLEAR DTC
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Read and record the DTCs and freeze frame data.
- Clear DTCs and freeze frame data.
- Turn the power switch off.
NEXT: Go to next step
- CHECK DTC OUTPUT (HYBRID CONTROL)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Perform a road test.
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Check if DTCs are output.
Result
Result Proceed to No DTCs are output. A P082B-575, P082C-576, P082E-571, P082F-572, P181A-596, P181B-595, P182B-577, P182C-578, P182E-573 or P182F-574 is output again. B - Turn the power switch off.
B → See step 20
A → COMPLETED
- CHECK HARNESS AND CONNECTOR (SHORT TO POWER SUPPLY WIRES)
- Remove the IGCT NO. 2 fuse and AM2 fuse from the engine room relay block and junction block assembly.Fig 9: Identifying IGCT No. 2 Fuse And AM2 Fuse & Engine Room Relay Block And Junction Block Assembly
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
TEXT IN ILLUSTRATION*1 Engine Room Relay Block and Junction Block Assembly *2 AM2 Fuse *3 IGCT NO. 2 Fuse - Disconnect connector L127 from the shift sensor.
- Disconnect all the connectors from the power management control ECU.
- Measure the resistance according to the value(s) in the table below.TEXT IN ILLUSTRATION
*a Rear view of wire harness connector
(to Power Management Control ECU)- - Standard Resistance
Tester Connection Switch Condition Specified Condition L5-26 (VCX1) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-26 (VCX1) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-26 (VCX1) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-26 (VCX1) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-26 (VCX1) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-26 (VCX1) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-26 (VCX1) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-26 (VCX1) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-26 (VCX1) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-26 (VCX1) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-26 (VCX1) - A21-16 (GI) Power switch off 10 kΩ or higher L5-26 (VCX1) - A21-4 (FCTL) Power switch off 10 kΩ or higher Standard Resistance
Tester Connection Switch Condition Specified Condition L5-25 (VSX1) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-25 (VSX1) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-25 (VSX1) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-25 (VSX1) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-25 (VSX1) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-25 (VSX1) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-25 (VSX1) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-25 (VSX1) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-25 (VSX1) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-25 (VSX1) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-25 (VSX1) - A21-16 (GI) Power switch off 10 kΩ or higher L5-25 (VSX1) - A21-4 (FCTL) Power switch off 10 kΩ or higher Standard Resistance
Tester Connection Switch Condition Specified Condition L5-24 (E2X1) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-24 (E2X1) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-24 (E2X1) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-24 (E2X1) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-24 (E2X1) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-24 (E2X1) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-24 (E2X1) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-24 (E2X1) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-24 (E2X1) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-24 (E2X1) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-24 (E2X1) - A21-16 (GI) Power switch off 10 kΩ or higher L5-24 (E2X1) - A21-4 (FCTL) Power switch off 10 kΩ or higher Standard Resistance
Tester Connection Switch Condition Specified Condition L5-21 (VCX2) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-21 (VCX2) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-21 (VCX2) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-21 (VCX2) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-21 (VCX2) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-21 (VCX2) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-21 (VCX2) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-21 (VCX2) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-21 (VCX2) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-21 (VCX2) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-21 (VCX2) - A21-16 (GI) Power switch off 10 kΩ or higher L5-21 (VCX2) - A21-4 (FCTL) Power switch off 10 kΩ or higher Standard Resistance
Tester Connection Switch Condition Specified Condition L5-22 (VSX2) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-22 (VSX2) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-22 (VSX2) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-22 (VSX2) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-22 (VSX2) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-22 (VSX2) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-22 (VSX2) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-22 (VSX2) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-22 (VSX2) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-22 (VSX2) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-22 (VSX2) - A21-16 (GI) Power switch off 10 kΩ or higher L5-22 (VSX2) - A21-4 (FCTL) Power switch off 10 kΩ or higher Standard Resistance
Tester Connection Switch Condition Specified Condition L5-23 (E2X2) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-23 (E2X2) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-23 (E2X2) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-23 (E2X2) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-23 (E2X2) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-23 (E2X2) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-23 (E2X2) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-23 (E2X2) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-23 (E2X2) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-23 (E2X2) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-23 (E2X2) - A21-16 (GI) Power switch off 10 kΩ or higher L5-23 (E2X2) - A21-4 (FCTL) Power switch off 10 kΩ or higher - Connect the power management control ECU connectors.
- Connect the shift sensor connector.
- Install the IGCT NO. 2 fuse and AM2 fuse.
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 20
- Remove the IGCT NO. 2 fuse and AM2 fuse from the engine room relay block and junction block assembly.
- CHECK HARNESS AND CONNECTOR (SHORT TO POWER SUPPLY WIRES)
- Remove the IGCT NO. 2 fuse and AM2 fuse from the engine room relay block and junction block assembly.Fig 11: Identifying IGCT No. 2 Fuse And AM2 Fuse & Engine Room Relay Block And Junction Block Assembly
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
TEXT IN ILLUSTRATION*1 Engine Room Relay Block and Junction Block Assembly *2 AM2 Fuse *3 IGCT NO. 2 Fuse - Disconnect connector L126 from the select sensor.
- Disconnect all the connectors from the power management control ECU.
- Measure the resistance according to the value(s) in the table below.TEXT IN ILLUSTRATION
*a Rear view of wire harness connector
(to Power Management Control ECU)- - Standard Resistance
Tester Connection Switch Condition Specified Condition L5-19 (VCX3) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-19 (VCX3) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-19 (VCX3) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-19 (VCX3) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-19 (VCX3) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-19 (VCX3) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-19 (VCX3) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-19 (VCX3) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-19 (VCX3) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-19 (VCX3) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-19 (VCX3) - A21-16 (GI) Power switch off 10 kΩ or higher L5-19 (VCX3) - A21-4 (FCTL) Power switch off 10 kΩ or higher Standard Resistance
Tester Connection Switch Condition Specified Condition L5-20 (VSX3) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-20 (VSX3) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-20 (VSX3) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-20 (VSX3) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-20 (VSX3) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-20 (VSX3) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-20 (VSX3) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-20 (VSX3) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-20 (VSX3) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-20 (VSX3) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-20 (VSX3) - A21-16 (GI) Power switch off 10 kΩ or higher L5-20 (VSX3) - A21-4 (FCTL) Power switch off 10 kΩ or higher Standard Resistance
Tester Connection Switch Condition Specified Condition L5-17 (VCX4) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-17 (VCX4) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-17 (VCX4) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-17 (VCX4) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-17 (VCX4) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-17 (VCX4) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-17 (VCX4) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-17 (VCX4) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-17 (VCX4) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-17 (VCX4) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-17 (VCX4) - A21-16 (GI) Power switch off 10 kΩ or higher L5-17 (VCX4) - A21-4 (FCTL) Power switch off 10 kΩ or higher Standard Resistance
Tester Connection Switch Condition Specified Condition L5-18 (VSX4) - A21-2 (+B2) Power switch off 10 kΩ or higher L5-18 (VSX4) - A22-5 (+B1) Power switch off 10 kΩ or higher L5-18 (VSX4) - L5-1 (AM22) Power switch off 10 kΩ or higher L5-18 (VSX4) - L6-7 (AM21) Power switch off 10 kΩ or higher L5-18 (VSX4) - A22-6 (MREL) Power switch off 10 kΩ or higher L5-18 (VSX4) - A22-1 (IG2) Power switch off 10 kΩ or higher L5-18 (VSX4) - L6-1 (ACCD) Power switch off 10 kΩ or higher L5-18 (VSX4) - L6-2 (IG1D) Power switch off 10 kΩ or higher L5-18 (VSX4) - A22-2 (IG2D) Power switch off 10 kΩ or higher L5-18 (VSX4) - L5-14 (SPDI) Power switch off 10 kΩ or higher L5-18 (VSX4) - A21-16 (GI) Power switch off 10 kΩ or higher L5-18 (VSX4) - A21-4 (FCTL) Power switch off 10 kΩ or higher - Connect the power management control ECU connectors.
- Connect the select sensor connector.
- Install the IGCT NO. 2 fuse and AM2 fuse.
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 20
- Remove the IGCT NO. 2 fuse and AM2 fuse from the engine room relay block and junction block assembly.
- REPLACE POWER MANAGEMENT CONTROL ECU. Refer to COMPONENTS