DTC B1507: Open in Turn Signal Circuit; DTC B1508: Short in Turn Signal / Hazard Flasher Circuit: Procedure
- INSPECT LIGHTS
- Inspect the illumination of each turn signal light.RESULT
Result Proceed to Turn signal lights for one side do not illuminate. A Front turn signal light does not illuminate. B Rear turn signal light does not illuminate. C
B → See step 3
C → See step 4
A: Go to next step
- Inspect the illumination of each turn signal light.
- CHECK HARNESS AND CONNECTOR (COMBINATION METER SUB-ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK)
- Disconnect the L125 combination meter sub-assembly connector.
- Disconnect the 2A instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open)
FOR LHTester Connection Condition Specified Condition L125-3 (LL) - 2A-22 Always Below 1 Ω FOR RHTester Connection Condition Specified Condition L125-5 (LR) - 2A-17 Always Below 1 Ω Standard Resistance (Check for Short)
FOR LHTester Connection Condition Specified Condition L125-3 (LL) - Body ground Always 10 kΩ or higher FOR RHTester Connection Condition Specified Condition L125-5 (LR) - Body ground Always 10 kΩ or higher RESULTResult Proceed to NG A OK B
B → See step 5
A → REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (FRONT TURN SIGNAL LIGHT - INSTRUMENT PANEL JUNCTION BLOCK)
- Disconnect the C3*1 or C5*2 front turn signal light connector.
- *1: for LH
- *2: for RH
- Disconnect the 2C instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open)
FOR LHTester Connection Condition Specified Condition C3-1 (B) - 2C-17 Always Below 1 Ω C3-2 (E) - Body ground Always Below 1 Ω FOR RHTester Connection Condition Specified Condition C5-1 (B) - 2C-36 Always Below 1 Ω C5-2 (E) - Body ground Always Below 1 Ω Standard Resistance (Check for Short)
FOR LHTester Connection Condition Specified Condition C3-1 (B) - Body ground Always 10 kΩ or higher FOR RHTester Connection Condition Specified Condition C5-1 (B) - Body ground Always 10 kΩ or higher RESULTResult Proceed to NG A OK B
B → See step 5
A → REPAIR OR REPLACE HARNESS OR CONNECTOR
- Disconnect the C3*1 or C5*2 front turn signal light connector.
- CHECK HARNESS AND CONNECTOR (REAR TURN SIGNAL LIGHT - INSTRUMENT PANEL JUNCTION BLOCK)
- Disconnect the R17*1 or S18*2 rear turn signal light connector.
- *1: for LH
- *2: for RH
- Disconnect the 2D instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open)
FOR LHTester Connection Condition Specified Condition R17-6 (B) - 2D-17 Always Below 1 Ω R17-5 (E) - Body ground Always Below 1 Ω FOR RHTester Connection Condition Specified Condition S18-6 (B) - 2D-4 Always Below 1 Ω S18-5 (E) - Body ground Always Below 1 Ω Standard Resistance (Check for Short)
FOR LHTester Connection Condition Specified Condition R17-6 (B) - Body ground Always 10 kΩ or higher FOR RHTester Connection Condition Specified Condition S18-6 (B) - Body ground Always 10 kΩ or higher RESULTResult Proceed to NG A OK B
B → See step 5
A → REPAIR OR REPLACE HARNESS OR CONNECTOR
- Disconnect the R17*1 or S18*2 rear turn signal light connector.
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
- Remove the instrument panel junction block assembly. Refer to REMOVAL .
- Remove the main body ECU (multiplex network body ECU).
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 2A-22 - 2C-17 Always Below 1 Ω 2A-22 - 2D-17 Always Below 1 Ω 2A-17 - 2C-36 Always Below 1 Ω 2A-17 - 2C-4 Always Below 1 Ω
NG → See step 7
OK → See step 6
- REPLACE METER CIRCUIT PLATE. Refer to DISASSEMBLY
- REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL