Home >> Toyota >> 2012 >> Prius V >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Meter / Gauge System (Diagnostic Codes & Symptom Tests) >> Meter / Gauge System >> DTC B1507: Open in Turn Signal Circuit; DTC B1508: Short in Turn Signal / Hazard Flasher Circuit >> Procedure

DTC B1507: Open in Turn Signal Circuit; DTC B1508: Short in Turn Signal / Hazard Flasher Circuit: Procedure

  1. INSPECT LIGHTS 
    1. Inspect the illumination of each turn signal light.
      RESULT

      Result Proceed to
      Turn signal lights for one side do not illuminate. A
      Front turn signal light does not illuminate. B
      Rear turn signal light does not illuminate. C

    B → See step   3 

    C → See step   4 

    A: Go to next step 

  2. CHECK HARNESS AND CONNECTOR (COMBINATION METER SUB-ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK) 
    1. Disconnect the L125 combination meter sub-assembly connector.
    2. Disconnect the 2A instrument panel junction block assembly connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)

      FOR LH

      Tester Connection Condition Specified Condition
      L125-3 (LL) - 2A-22 Always Below 1 Ω
      FOR RH

      Tester Connection Condition Specified Condition
      L125-5 (LR) - 2A-17 Always Below 1 Ω

      Standard Resistance (Check for Short)

      FOR LH

      Tester Connection Condition Specified Condition
      L125-3 (LL) - Body ground Always 10 kΩ or higher
      FOR RH

      Tester Connection Condition Specified Condition
      L125-5 (LR) - Body ground Always 10 kΩ or higher
      RESULT

      Result Proceed to
      NG A
      OK B

    B → See step   5 

    A → REPAIR OR REPLACE HARNESS OR CONNECTOR 

  3. CHECK HARNESS AND CONNECTOR (FRONT TURN SIGNAL LIGHT - INSTRUMENT PANEL JUNCTION BLOCK) 
    1. Disconnect the C3*1 or C5*2 front turn signal light connector.
      • *1: for LH
      • *2: for RH
    2. Disconnect the 2C instrument panel junction block assembly connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)

      FOR LH

      Tester Connection Condition Specified Condition
      C3-1 (B) - 2C-17 Always Below 1 Ω
      C3-2 (E) - Body ground Always Below 1 Ω
      FOR RH

      Tester Connection Condition Specified Condition
      C5-1 (B) - 2C-36 Always Below 1 Ω
      C5-2 (E) - Body ground Always Below 1 Ω

      Standard Resistance (Check for Short)

      FOR LH

      Tester Connection Condition Specified Condition
      C3-1 (B) - Body ground Always 10 kΩ or higher
      FOR RH

      Tester Connection Condition Specified Condition
      C5-1 (B) - Body ground Always 10 kΩ or higher
      RESULT

      Result Proceed to
      NG A
      OK B

    B → See step   5 

    A → REPAIR OR REPLACE HARNESS OR CONNECTOR 

  4. CHECK HARNESS AND CONNECTOR (REAR TURN SIGNAL LIGHT - INSTRUMENT PANEL JUNCTION BLOCK) 
    1. Disconnect the R17*1 or S18*2 rear turn signal light connector.
      • *1: for LH
      • *2: for RH
    2. Disconnect the 2D instrument panel junction block assembly connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)

      FOR LH

      Tester Connection Condition Specified Condition
      R17-6 (B) - 2D-17 Always Below 1 Ω
      R17-5 (E) - Body ground Always Below 1 Ω
      FOR RH

      Tester Connection Condition Specified Condition
      S18-6 (B) - 2D-4 Always Below 1 Ω
      S18-5 (E) - Body ground Always Below 1 Ω

      Standard Resistance (Check for Short)

      FOR LH

      Tester Connection Condition Specified Condition
      R17-6 (B) - Body ground Always 10 kΩ or higher
      FOR RH

      Tester Connection Condition Specified Condition
      S18-6 (B) - Body ground Always 10 kΩ or higher
      RESULT

      Result Proceed to
      NG A
      OK B

    B → See step   5 

    A → REPAIR OR REPLACE HARNESS OR CONNECTOR 

  5. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY 
    1. Remove the instrument panel junction block assembly. Refer to REMOVAL .
    2. Remove the main body ECU (multiplex network body ECU).
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      2A-22 - 2C-17 Always Below 1 Ω
      2A-22 - 2D-17 Always Below 1 Ω
      2A-17 - 2C-36 Always Below 1 Ω
      2A-17 - 2C-4 Always Below 1 Ω

    NG → See step   7 

    OK → See step   6 

  6. REPLACE METER CIRCUIT PLATE. Refer to  DISASSEMBLY 
  7. REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to  REMOVAL