DTC B1500: Fuel Sender Open Detected: Procedure
- READ VALUE USING TECHSTREAM (FUEL INPUT)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Check the values by referring to the table below.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Fuel Input Fuel input/Min.: 0, Max.: 127.5 10th segment comes on:
39.6 to 45Unit: Liter 9th segment comes on:
35.9 to 39.68th segment comes on:
32.0 to 35.97th segment comes on:
27.8 to 32.06th segment comes on:
23.6 to 27.85th segment comes on:
19.4 to 23.64th segment comes on:
15.3 to 19.43rd segment comes on:
12.1 to 15.32nd segment comes on:
8.1 to 12.11st segment comes on:
5.1 to 8.1Result
Result Proceed to Fuel level data can be displayed on the Techstream. A Fuel level data cannot be displayed on the Techstream. B
B → See step 2
A → See step 5
- INSPECT FUEL SENDER GAUGE ASSEMBLY
- Disconnect the L27 connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition L27-12 (L) - L27-13 (ES 2) Always 12 to 415 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Combination Meter Sub-assembly)
NG → See step 3
OK → See step 5
- CHECK HARNESS AND CONNECTOR (COMBINATION METER SUB-ASSEMBLY - FUEL SENDER GAUGE ASSEMBLY)
- Disconnect the R11 connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition L27-12 (L) - R11-2 (FS) Always Below 1 Ω L27-12 (L) - Body ground Always 10 kΩ or higher L27-13 (ES 2) - R11-3 (FE) Always Below 1 Ω L27-13 (ES 2) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- INSPECT FUEL SENDER GAUGE ASSEMBLY
- Remove the fuel sender gauge assembly. Refer to REMOVAL .
- Check that the float moves smoothly between E and F.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 Float level is F (upper) 12 to 18 Ω 1 - 2 Float level is between F (upper) and E (lower) 12 to 415 Ω (Gradually changes) 1 - 2 Float level is E (lower) 405 to 415 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Fuel Sender Gauge Assembly)
NG → See step 6
OK → See step 5
- REPLACE METER CIRCUIT PLATE. Refer to DISASSEMBLY
- REPLACE FUEL SENDER GAUGE ASSEMBLY. Refer to REMOVAL