Operating Light Control Rheostat does not Change Light Brightness: Procedure
- SYSTEM CHECK
- Confirm the symptoms.
Result
Result Proceed to Meter illumination does not change in operating the light control rheostat. A Dimmer function cannot be canceled. B
B → See step 6
A: Go to next step
- Confirm the symptoms.
- READ VALUE USING TECHSTREAM (RHEOSTAT VALUE)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Check the values by referring to the table below.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Rheostat value Light control rheostat/Min.: 0 (dark), Max.: 255 (bright) The light control rheostat value 0 (dark) The value changes with the rheostat operation The light control rheostat value 255 (bright) OK
The value displayed on the Techstream gradually changes as the actual rheostat knob operation.
NG → See step 4
OK: Go to next step
- READ VALUE USING TECHSTREAM (TAIL CANCEL SW)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Check the values by referring to the table below.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Tail Cancel SW Tail cancel switch/OFF or ON OFF: Tail cancel switch off - ON: Tail cancel switch on - HINT:
The tail cancel switch is operated by turning the light control rheostat knob fully upward
OK
Condition displayed on the Techstream is the same as the actual light control rheostat knob position.
NG → See step 7
OK → See step 9
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 1 (E) - 3 (TR) Turn the light control rheostat knob fully downwards (MIN.) Below 50 Ω Light control rheostat knob position is between MIN. and MAX. The value changes gradually (Between 0 to 12 kΩ) Turn the light control rheostat knob fully upwards (MAX.) 8 to 12 kΩ TEXT IN ILLUSTRATION*1 Component without harness connected
(Light Control Rheostat)
NG → See step 10
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (NO. 3 METER CIRCUIT PLATE - LIGHT CONTROL RHEOSTAT)
- Disconnect the L27 and L59 connectors.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition L27-37 (SW2) - L59-3 (TR) Always Below 1 Ω L27-37 (SW2) - Body ground Always 10 kΩ or higher L27-38 (SW3) - L59-1 (E) Always Below 1 Ω L27-38 (SW3) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 9
- READ VALUE USING TECHSTREAM (TAIL CANCEL SW)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Check the values by referring to the table below.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Tail Cancel SW Tail cancel switch/OFF or ON OFF: Tail cancel switch off - ON: Tail cancel switch on - HINT:
The tail cancel switch is operated by turning the light control rheostat knob fully upward
OK
Condition displayed on the Techstream is the same as the actual light control rheostat knob position.
NG → See step 7
OK: Go to next step
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 5 (TC) - 7 (T) Light control rheostat position is except below Below 50 Ω Turn the light control rheostat knob fully upwards (Tail cancel switch is on) 8 to 12 kΩ TEXT IN ILLUSTRATION*1 Component without harness connected
(Light Control Rheostat)
NG → See step 10
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (NO. 3 METER CIRCUIT PLATE - LIGHT CONTROL RHEOSTAT)
- Disconnect the L27 and L59 connectors.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition L27-36 (SW1) - L59-7 (T) Always Below 1 Ω L27-36 (SW1) - Body ground Always 10 kΩ or higher L27-35 (TC) - L59-5 (TC) Always Below 1 Ω L27-35 (TC) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 9
- REPLACE COMBINATION METER ASSEMBLY (NO. 3 METER CIRCUIT PLATE). Refer to DISASSEMBLY
- REPLACE LIGHT CONTROL RHEOSTAT. Refer to REMOVAL