Odo/Trip Switch Malfunction: Procedure
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Check the values by referring to the table below.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Timer Switch H on Combination Meter Timer switch H on combination meter/OFF or ON OFF: Hour adjust switch not pressed - ON: Hour adjust switch pressed Timer Switch M on Combination Meter Timer switch M on combination meter/OFF or ON OFF: Minute adjust switch not pressed - ON: Minute adjust switch pressed Timer Switch 00 on Combination Meter Timer switch 00 on combination meter/OFF or ON OFF: Reset switch not pressed - ON: Reset switch pressed OK
The value displayed on the Techstream changes as the actual switch operation.
NG → See step 2
OK → See step 4
- INSPECT TRIP SWITCH
- w/o Headup Display
- Remove the trip switch.
- w/ Headup Display
- Remove the trip switch.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 (CS) - 12 (E) Unit change switch pressed Below 1 Ω 1 (CS) - 12 (E) Unit change switch not pressed 10 kΩ or higher 9 (HOUR) - 12 (E) Hour adjust switch pressed Below 1 Ω 9 (HOUR) - 12 (E) Hour adjust switch not pressed 10 kΩ or higher 10 (MIN) - 12 (E) Minute adjust switch pressed Below 1 Ω 10 (MIN) - 12 (E) Minute adjust switch not pressed 10 kΩ or higher 11 (RST) - 12 (E) Set switch pressed Below 1 Ω 11 (RST) - 12 (E) Set switch not pressed 10 kΩ or higher TEXT IN ILLUSTRATION*1 Component without harness connected
(Trip Switch)*2 Component without harness connected
(Trip Switch)
NG → See step 5
OK: Go to next step
- w/o Headup Display
- CHECK HARNESS AND CONNECTOR (NO. 3 METER CIRCUIT PLATE - TRIP SWITCH)
- Disconnect the L27 and L57 connectors.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition L27-2 (TC O) - L57-1 (CS) Always Below 1 Ω L27-2 (TC O) - Body ground Always 10 kΩ or higher L27-12 (HOUR) - L57-9 (HOUR) Always Below 1 Ω L27-12 (HOUR) - Body ground Always 10 kΩ or higher L27-13 (MIN) - L57-10 (MIN) Always Below 1 Ω L27-13 (MIN) - Body ground Always 10 kΩ or higher L27-17 (RST) - L57-11 (RST) Always Below 1 Ω L27-17 (RST) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 4
- REPLACE COMBINATION METER ASSEMBLY (NO. 3 METER CIRCUIT PLATE). Refer to DISASSEMBLY
- REPLACE TRIP SWITCH. Refer to REMOVAL