Home >> Toyota >> 2012 >> Highlander Limited, FWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 115 (Hybrid Vehicle Control System (Diagnostic Codes (P0ADB-227 - U0424-537) & Circuit Tests)) (Hybrid)) >> Hybrid Control System >> DTC P0AE6-225: Hybrid Battery Precharge Contactor Control Circuit Low; DTC P0AE7-224: Hybrid Battery Precharge Contactor Control Circuit High >> Description

DTC P0AE6-225: Hybrid Battery Precharge Contactor Control Circuit Low; DTC P0AE7-224: Hybrid Battery Precharge Contactor Control Circuit High: Description

WARNING: This page is about a different variant/trim than selected.

The SMRs (System Main Relays) are the relays that connect or disconnect the high voltage power system in accordance with commands from the hybrid vehicle control ECU.

There are 3 SMRs and 1 precharge resistor. SMRB, SMRP, SMRG, and the precharge resistor are located in the HV battery junction block assembly in the HV battery pack.

To connect to the high voltage power system, the vehicle will first turn on SMRP and SMRB to charge the vehicle through the system main resistor. Then, SMRP will be turned off after SMRG is turned on. To shut off the high voltage power system, SMRB and SMRG are turned off.

DTC No. INF Code DTC Detection Condition Trouble Area
P0AE6 225 Short to GND in the SMRP circuit
  • Wire harness or connector
  • Hybrid battery junction block assembly
  • Hybrid vehicle control ECU
P0AE7 224 Open or +B short in SMRP circuit